85 Franklin Rd
Dover, NJ 07801
973-366-8754

Local Reviews
for saddle river, nj

Rated 5.0 out of 5 stars based on 3 customer reviews

Very knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast and reliable service

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for saddle river, nj

Kurt B.

Kurt B. Job Checkin

Winterization complete


Christian R.

Christian R. Job Checkin

Winterization We have completed a thorough winterization of your irrigation system. Please leave all irrigation shut-off valves closed to prevent re-introducing water into your system, which could cause freeze damage. If you notice any water dripping outside, or icicle formations on irrigation pipes, please call us to schedule having your shut-off valve replaced immediately. We look forward to starting up and inspecting your system in the Spring! Don’t forget to renew your annual membership, if you haven’t already! Any necessary repairs or upgrades were identified and recommendations provided.


Dwayne P.

Dwayne P. Job Checkin

Winterization We have completed a thorough winterization of your irrigation system. Please leave all irrigation shut-off valves closed to prevent re-introducing water into your system, which could cause freeze damage. If you notice any water dripping outside, or icicle formations on irrigation pipes, please call us to schedule having your shut-off valve replaced immediately. We look forward to starting up and inspecting your system in the Spring! Don’t forget to renew your annual membership, if you haven’t already! Any necessary repairs or upgrades were identified and recommendations provided.


JP A.

JP A. Job Checkin

We have completed a thorough winterization of your irrigation system. Please leave all irrigation shut-off valves closed to prevent re-introducing water into your system, which could cause freeze damage. If you notice any water dripping outside, or icicle formations on irrigation pipes, please call us to schedule having your shut-off valve replaced immediately. We look forward to starting up and inspecting your system in the Spring! Don’t forget to renew your annual membership, if you haven’t already! Any necessary repairs or upgrades were identified and recommendations provided.


Dwayne P.

Dwayne P. Job Checkin

We have completed a thorough winterization of your irrigation system. Please leave all irrigation shut-off valves closed to prevent re-introducing water into your system, which could cause freeze damage. If you notice any water dripping outside, or icicle formations on irrigation pipes, please call us to schedule having your shut-off valve replaced immediately. We look forward to starting up and inspecting your system in the Spring! Don’t forget to renew your annual membership, if you haven’t already! Any necessary repairs or upgrades were identified and recommendations provided. Polly break zone 2 Zone 5 Riser and rotary head broken


Matt H.

Matt H. Job Checkin

Zone 3- Rebury (1) rotor that is too high and slightly crooked Zone 4- Replace (1) clogged and non retracting rotor and move approx 1.5 ft closer to driveway for better coverage (may not be possible due to possible concrete overpour from newly installed Belgium block driveway, but will not know this until it is dug up) Zone 7- Replace (1) non rotating rotor and move approx 2 ft closer to driveway for better coverage (may not be possible due to possible concrete overpour from newly installed Belgium block driveway, but will not know this until it is dug up) and raise/replace (1) non retracting rotor that is buried for better coverage *after digging up heads, found I was able to move them closer to Belgium block without any issues. ___________________________________________________________________ *All Wet is not responsible for any unmarked under ground utilities. *Landscaper may need to do minor cleanup/top dressing after repairs. *Further repairs may be needed once system is ful


JP A.

JP A. Job Checkin

Add spray head near mailbox for better coverage Zone8 has a continuous flow of water coming out of heads indicating a possible weeping valve for that particular zone….replaced zone valve free of charge and issue stopped ….recommend installing a filter and possibly replacing master valve


Christian R.

Christian R. Job Checkin

We just completed your mid-season inspection, and we wanted to provide you with an update on the valuable services we've performed to ensure your irrigation system continues to perform optimally for a lush and healthy landscape. Here's a technical breakdown of the tasks we've completed: ___________________________________________________________________ Leak-Free Performance: We pressurized your system to detect any leaks. By addressing leaks promptly, we prevent water waste, save you money on utility bills, and preserve our precious resources. Optimal Coverage: Our team adjusted your sprinkler heads to guarantee proper coverage. This means every inch of your landscape receives the right amount of water, minimizing dry spots and ensuring a lush, healthy environment. Smart Timing: We've set your timer based on the current weather and seasonal conditions. By aligning watering schedules with the unique needs of your plants, we maximize water efficiency and prevent over or under-waterin


Matt H.

Matt H. Job Checkin

SRC Controller (Garage): Zone 2- Add (2) 4” spray heads to better cover rear left grass area between house and pool Zone 7- Replace (1) rotor and add (1) rotor to better cover grass area behind pool Pro C Controller (Behind Shed) Zone 1- Low pressure, replace (6) standard spray nozzles with (6) MP nozzles Zone 2- Replace (1) broken 12” spray and replace (1) 12” spray with 4” spray for better coverage of grass area near bottom of steps leading from pool to pond *Notified homeowner that coverage could be slightly better in the areas mentioned above, however I think main issue is some sort of fungus growing in the lawn. Pictures posted to customer account, and let her know that we offer lawn care as well to help remedy these kinds of issues. ___________________________________________________________________ *All Wet is not responsible for any unmarked under ground utilities. *Landscaper may need to do minor cleanup/top dressing after repairs. *Further repairs may be needed once


Matt H.

Matt H. Job Checkin

Zone 7- Adjusted rotor along right side of driveway spraying into driveway near garage Zone 12- are buried 6” spray head at grade that was sticking up too high; this was also the zone that customer thought there may be a leaking head, checked area of concern and found head was not actually leaking; seemed like it was a combination of low head drainage, as well as head spraying into boxwood and coming straight down creating a small puddle (area is also underneath a tree where there is a lot of shade and water does not dry up as easily), turned off last spray head on zone in this area to help reduce amount of water that puddles in this area, customer will monitor, explained to him that some water will still puddle a little in this area and that it is normal and doesn’t necessarily mean there is a leak in the irrigation piping/head). *No charge for visit today*


Dwayne P.

Dwayne P. Job Checkin

Installation of a 1 zone add on to existing system _____________________________________________________________________________________ Design Using zone 1 feed line, that is stubbed out to the right of driveway. To irrigate boxwoods and tree by street. - Water is on at the house and irrigation main - shut off handles are open at the backflow device and water is present at test ports - water is present when blowout port is open MP rotor side strip nozzles - Has spare zone right of driveway connected to zone 1 in timer Customer stays he has not timer but used hydrawise app each valve seems to be connected to a single station decode *2 man crew approx. 3 hours* _____________________________________________________________________________________ _____________________________________________________________________________________ *Overspray plant beds where ever possible. *Landscaper may need to do minor cleanup/top dressing after installation. *All Wet will request a utilit


JP A.

JP A. Job Checkin

Moved 3 heads recently installed Also wrote estimate to add new zone to front


Dwayne P.

Dwayne P. Job Checkin

___________________________________________________________________ Pressurized the system to check for leaks, adjusted sprinkler heads for proper coverage, and set the timer based on current weather and seasonal conditions. Inspected the system for any issues and provided recommendations for repairs or upgrades as needed. With these services completed, your irrigation system is now running efficiently and effectively. ___________________________________________________________________ Inspection Report Zone 1: Zone is operational at this time. Zone 2: Zone is operational at this time. Zone 3: Zone is operational at this time. Zone 4: Zone is operational at this time. Zone 5: Zone is operational at this time. Zone 6: Zone is operational at this time. Zone 7: Add a new rotary head Zone 8: Zone is operational at this time. Zone 9: Zone is operational at this time. Zone 10: Zone is operational at this time. Zone 11: Zone is operational at this time. Zone 12: Zone is operational at this


Michael H.

Michael H. Job Checkin

12 zones total. Troubleshoot low pressure on zone 12; Found 1 rotary head jammed from sand/sediment, was able to pull it up and clean it, however I recommended to replace it. Tested zones 10&11 and determined that the pressure is the same or not much better. Also found another head jammed, and was able to pull it up and clean it a little. Assessed zone valves in valve box: no problem found there. Assessed the well tank and plumbing: all valves are fully open. Pressure gauge at well tank reads approx 33 psi and stays steady…was not climbing. Advised customer that it is possible that the well pump is not performing 100%. It is also possible that the well tank is not functioning properly. Suggest having a well company service and set the flow rate performance. Current system is designed to require at least 15 gpm flow, since there are at least 6 heads per zone.


JP A.

JP A. Job Checkin

___________________________________________________________________ Pressurized the system to check for leaks, adjusted sprinkler heads for proper coverage, and set the timer based on current weather and seasonal conditions. Inspected the system for any issues and provided recommendations for repairs or upgrades as needed. With these services completed, your irrigation system is now running efficiently and effectively. ___________________________________________________________________ Inspection Report Zone 1: Zone is operational at this time. Zone 2: Zone is operational at this time. Zone 3: Zone is operational at this time. Zone 4: Zone is operational at this time. Zone 5: broken 6” mist. Zone 6: leaking rotor. Zone 7: Zone is operational at this time. Zone 8: Zone is operational at this time. Zone 9: Zone is operational at this time. Zone 10: broken 6” mist broken 4” both Mp nozzle. Zone 11: Zone is operational at this time. Zone 12: Zone is operational at this time.. ___________