Dwayne P.

Dwayne P. Job Checkin

We have completed a thorough winterization of your irrigation system. Please leave all irrigation shut-off valves closed to prevent re-introducing water into your system, which could cause freeze damage. If you notice any water dripping outside, or icicle formations on irrigation pipes, please call us to schedule having your shut-off valve replaced immediately. We look forward to starting up and inspecting your system in the Spring! Don’t forget to renew your annual membership, if you haven’t already! Any necessary repairs or upgrades were identified and recommendations provided.


Dwayne P.

Dwayne P. Job Checkin

Check the backflow upon arrival. Backflow was frozen. Opened test ports while water was on and nothing came out. Possibly going to need to replace backflow (free of charge).


Dwayne P.

Dwayne P. Job Checkin

Winterization completed -zone 14 stock valve and broken head


Dwayne P.

Dwayne P. Job Checkin

Head was off of the fitting. I retreaded it. Flushed the head out. Head was full of dirt so I flushed it out to the best of my ability. Showed Joe that it was turning on and that if it needs to be replaced to give a call and I would come back and replace it.


Dwayne P.

Dwayne P. Job Checkin

___________________________________________________________________ Pressurized the system to check for leaks, adjusted sprinkler heads for proper coverage, and set the timer based on current weather and seasonal conditions. Inspected the system for any issues and provided recommendations for repairs or upgrades as needed. With these services completed, your irrigation system is now running efficiently and effectively. ___________________________________________________________________ Inspection Report 1” rpz backflow preventer is dripping Took pressure reading during startup as some zones are a little weaker then others. Dynamic pressure is great around 30-45 psi. After finished with the inspection removed pressure gauge and the inside was all filled with sediment likely well is a little dirty. Likely will need valve replacements in the near future. They are ok at this time though. Recommend installing a view flow filter to catch sediment before it goes through the zone valves to


Dwayne P.

Dwayne P. Job Checkin

__________________________________________________________________________________ Inspection Report Zone 1 broken rotor top hill left Zone 2 low pressure Zone 3ok Zone 4 2 bubbling rotors bottom hill right Zone 5 didn’t come up orange wire Zone 6 knocking valve Zone 6 6 leaking rotors Zone 7ok Zone 8 bubbling rotor left side hill Zone 8 weeping zone valve Zone 9 doesn’t me on light red wire Zone 10 2 mulch sprays need to be put back into ground right side garage Zone 10 broken mulch spray left side garage Zone 11 doesn’t come on light blue wire Zone 12 cracked mist head right side Entrance island doesn’t come weeping zone and right side entrance island weeping zone doesnt come on Zone 13 underneath pavers front of building broken pipe don’t turn on Recommend to install in-line filter outside by backflow May need to wire find to find valves * prices are subject to change after initial repairs per Technician* __________________________________________________________________________


Chris D.

Chris D. Job Checkin

Timer Settings Program a zone 1-10 Program b 6-10 Start Time: program a 3am. program b 4am Days: program a even. Program b odd Water is off at backflow preventer as it is dripping. Timer was left off until repairs can be made