13 Lake Avenue
Helmetta, NJ 08828
(609)655-1073

Local Reviews
for plainsboro center, nj

Rated 5.0 out of 5 stars based on 2 customer reviews

Simply The Best

Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Dominic McGinley was very professional and very friendly. He explained to me what he was doing and finally what the problem was. He represents your company very well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for plainsboro center, nj

Dylan M.

Dylan M. Job Checkin

Tech arrived and was shown to kitchen sink, to which customer explained that it was leaking from the top, beneath the handle, as well as underneath the sink. Tech discussed options with customer. customer chose to diagnose faucet before opting to replace or repair faucet. Tech pulled mixing valve from faucet inspected and cleaned off. Mixing valve was put back in and tighten down Prior to turning water back on and testing. Tech ran sink testing both hot and cold on and off ensuring that the leak was no longer present.


Nick R.

Nick R. Job Checkin

Removed existing delta 1400 series shower cartridge and replaced with new. Upon removal of old cartridge, body became stuck inside valve and needed to be removed with proper tool. After removal of cartridge body, inspected inside of valve and found normal wear and tear and advised customer valve condition. Replaced cartridge with new and tested water temperature to ensure comfort No leaks at this time.


Dylan M.

Dylan M. Job Checkin

Customer had called company with a complaint of a rattling noise from the pipes in the unit. They had explained that the complex had sent out PSENG and told them that it was an isolated issue within the unit. Tech confirmed that it had been waterhammer coming from the unit, and the source was from a leaking faucet in the kitchen. Upon attempting to shut off The water supply valves underneath the sink tech found that they had failed and needed to be replaced as well as the faucet. Once authorized tech installed two new shut off valves under the sink as well as a new Moen single handle kitchen faucet. Upon turning the water back on in the unit , the master bathroom toilet would not stop filling. Given the age and condition of the parts of the toilet tech recommended replacing the toilet , but offered the option to replace the fill valve that had gone bad. Tech was authorized to replace the fill valve, no issues at this time. Water hammer is not present at this time


Dominic M.

Dominic M. Job Checkin

Unit doesn’t have air conditioning due to power surge and burnt out electrical components. Control board, tranformer and contactor and thermostat


Dominic M.

Dominic M. Job Checkin

💥financing available💥 Replace existing unit with a American standard up flow 80000 btu furnace with a through the wall condenser 100 % customer satisfaction guarantee 100 % performance guarantee Lowest price guarantee "No -charge" 1 - year warranty 10 year manufacturers warranty Professional installation All permits required and included in price 15 % energy savings(cooling) 10 % energy savings(heating) New thermostat New drain connections New transition into ductwork 3 year membership with R.A Nichols All technicians are 100% certified and highly qualified to work on equipment. All technicians are also drug and background tested for peace of mind for our customers.


Dominic M.

Dominic M. Job Checkin

40% deposit on estimate for new unit