Chandler D. Job Checkin

CUSTOMER STATED: customer stated that the upstairs bathroom was not providing hot water at the shower TECHNICIAN NOTES: when technician arrived today, we found that the water heater was functioning properly, and the upstairs shower had been taken apart by the customer and was attempted to make the repair RESOLUTION/RECOMMENDATIONS: one technician turned on the water to the upstairs bathtub. We found that there was no mechanical failure, and that the customer had to of accidentally put it back in the proper orientation for it to function properly. Customer is very interested in homecare club membership and would like that sent to her email. JOB NOTES: JOB STATUS: complete PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE OR WHO YOU SPOKE TO) ESTIMATES: ready


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

This is a complimentary estimate for My Georgia Plumber to provide and install a replacement gas log assembly for the Heatilator ND3630. The gas log assembly is model SRV4055-077 Called out today to install the gas logs for customer Shut off pilot light And removed glass from ground Removed old gas logs Installed new gas logs Relight pilot light Clean up work area Job compleat Payment compleat using cc on file


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

Customer states the toilet was leaking in the garage Upon inspection found the toilet to seem loose but could not get it to leak down stairs but the floor around the toilet is misshapen and pulling up from the floor Tech notes Called to get approval to pull and reset toilet and possibly replace flange and was send to voice mail Was unable to locate clean out Gave customer service’s estimate Estimate ready to send


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: There was a flood coming from under the kitchen sink TECHNICIAN NOTES: Upon further investigation found the emergency shut off valve (eso ) to have come apart due to it being cpvc valve glued onto pex pipe RESOLUTION/RECOMMENDATIONS: Install proper piping and make a proper transition turned water back on and checked for leaks Made repair checked for leaks No leaks at this time JOB NOTES: Gave customer quote to replace the (eso) under kitchen sink Was only able to replace the one that had come off JOB STATUS: COMPLETE/NOTCOMPLETE (RETURN TRIP NEEDED?) Compleat PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE OR WHO YOU SPOKE TO) 115hema ESTIMATES: (READY TO SEND OR NEED REVIEW) Ready to send


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: they had a leaking bath tub. TECHNICIAN NOTES: called out today to look at a leaking bath tub. While on site I found that the bath tub above the garage has a drain cap with the threads snapped off of it. Home owner had already takin the drain cap off to show the snapped piece of metal on the threads. RESOLUTION/RECOMMENDATIONS: we will need to come out and cut a whole under the waste and over flow in the garage ceiling. Once exposed we will removed the old waste and over and install a brand new one. JOB NOTES: could not locate clean out. Home owners hose bibs are off. Home owner wants to call chw and figure out why this job was not approved.


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: TECHNICIAN NOTES: RESOLUTION/RECOMMENDATIONS: JOB NOTES: JOB STATUS: COMPLETE/NOTCOMPLETE (RETURN TRIP NEEDED?) PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE OR WHO YOU SPOKE TO) ESTIMATES: (READY TO SEND OR NEED REVIEW)


James T.

James T. Job Checkin

The tenants complaint is that they have had the powder bath toilet back up with black water 3 times in the last year and when it happens there is a bubbling noise that comes from the kitchen sink We tested the system and nothing is backing up or acting clogged After testing the system spoke with tenant and they said the last time it happened it was raining We found the home is on septic and the tank is in the front yard we found a location in the yard that is very wet and we probed and found it is right over the tank At this point the a septic company needs to be sent out to assess the tank Job not completed No estimates are needed


e.jenkins@mygeorgiaplumber.com

e.jenkins@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: busted pipe TECHNICIAN NOTES:came out to diagnose a busted pipe in the master bath while on site we cut a 2' x 3' hole where the bust was and located cpvc piping which had cracked causing the leak. RESOLUTION/RECOMMENDATIONS: replace busted cpvc with pex. JOB NOTES: no visible cleanout, water is off to home and cannot turn on without spraying water everywhere so I am unable to get home water pressure. JOB STATUS: not complete PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: denied ESTIMATES: ready to send


gio.barreto@mygeorgiaplumber.com

gio.barreto@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: They had a leak showing up in the living room area, and washing machine closet. TECHNICIAN NOTES: Upon inspection I found that there was a spraying noise, and leak coming from behind the drywall connected to the living room, and washing machine room. After cutting into the drywall I found that there is a pin hole leak coming from the 1/2” copper piping. I found that the hot/cold pipes are sitting directly next to each other which will make it difficult to make repair, and will require us to cut out both hot/cold pipes out for washing machine. I let h/o know I have waited my 10-15 mins with no response from choice warranty, and I would have to leave the job site unless she wants todays repairs done through service. The h/o elected to wait for warranty response before proceeding. RESOLUTION/RECOMMENDATIONS: We will need to cut out the hot/cold water lines for the washing machine where pin hole is located, and rework with new pex piping/fittings to help fix/preve


gio.barreto@mygeorgiaplumber.com

gio.barreto@mygeorgiaplumber.com Job Checkin

This is a choice estimate to repair the leaks on the 3/4 copper water line in the laundry room wall. **Gios Notes** Resolution: I was able to successfully cut out 1’-2’ of 3/4” copper piping, and replace with brand new 3/4” pex piping with no issues. I fully pressurized whole home with no further plumbing issues or leaks. Job Notes:**Please bill out the remaining balance for todays completed work to choice warranty**This home is on septic, and there is not external c/o** Job Status: Complete Autho: Choice has approved the work for todays trip, and just need to collect for remaining balance. Estimates: N/A


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: TECHNICIAN NOTES: RESOLUTION/RECOMMENDATIONS: JOB NOTES: JOB STATUS: COMPLETE/NOTCOMPLETE (RETURN TRIP NEEDED?) PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE OR WHO YOU SPOKE TO) ESTIMATES: (READY TO SEND OR NEED REVIEW)


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED:clogged toilet TECHNICIAN NOTES:came out today to diagnose a clogged toilet while on site found master bath toilet to be clogged. RESOLUTION/RECOMMENDATIONS:auger master bath toilet. After augering system was tested with success. JOB NOTES:no clean out, we needed to auger toilet before autho to properly diagnose if toilet was affected or main line. After we augered it cleared the upstairs clog.. JOB STATUS: COMPLETE PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: submitted but not received ESTIMATES: Complementary Estimate to auger the master bath toilet


p.brown@mygeorgiaplumber.com

p.brown@mygeorgiaplumber.com Job Checkin

CUSTOMER STATED: TECHNICIAN NOTES: RESOLUTION/RECOMMENDATIONS: JOB NOTES: JOB STATUS: COMPLETE/NOTCOMPLETE (RETURN TRIP NEEDED?) PARTS: (IF INCOMPLETE ARE STOCK OR SPECIAL ORDER PARTS NEEDED?) AUTHO: (AUTHO CODE OR WHO YOU SPOKE TO) ESTIMATES: (READY TO SEND OR NEED REVIEW)


gio.barreto@mygeorgiaplumber.com

gio.barreto@mygeorgiaplumber.com Job Checkin

Customer Stated: She had a leak coming from her master bathroom sink, the basement shower was only getting hot water, and the upstairs gayest bathroom was not getting enough hot water. Tech Notes: Upon inspection I found that there were no leaks coming from the upstairs master bathroom sink. We ran water for several minutes with no issues. I found that the basement stand alone shower was a moen brushed nickel trim, and I found that this handle is broken, and is missing a set screw along with broken missing parts for the handle/cartridge. I let the home owner know I would recommend to ResiPro to have the entire trim along with posi temp moen cartridge replaced. I found that the upstairs guest bathroom shower/tub has a temperature limiter, and it just needs to be adjusted. While on site I checked whole home water pressure, and received a reading of 115 psi which is outside of state code regulations which indicates that the PRV has failed, and will need to be replaced. Resolution: I


David C.

David C. Job Checkin

CUSTOMER STATED: leak on copper pipe in laundry closet wall. TECHNICIAN NOTES: found a 3/4 copper line in the wall behind the water heater leaking, customer has wrapped tape around the leak to slow it down. Submitted repairs through choice portal and waited 10+ minutes. RESOLUTION/RECOMMENDATIONS: section will need to be cut out and replaced. JOB NOTES: presented service option to customer, they would like to wait for choice approval. JOB STATUS: COMPLETE AUTHO: submitted through portal, no response at this time. ESTIMATES: READY TO SEND