Backwater Valve Installation: To shield a large office complex from potential sewer backups, we installed backwater valves in strategic locations. Our team handled precise excavation, professional installation, and system testing to ensure long-term protection and peace of mind.
Performed new sewer connection for residential property in Goldsboro. Project involved connecting home to municipal sewer system following septic system failure. Installation required 85 feet of 4-inch schedule 40 PVC pipe from house to municipal main. Excavated trench to appropriate depth maintaining required 1/4" per foot slope for proper gravitational flow. Encountered unexpected rock formation at approximately 40 feet from structure which necessitated use of pneumatic hammer. Successfully tied into municipal main using appropriate wye fitting as specified by city code. Installed cleanout at property line per regulations. All connections pressure tested and inspected by municipal authorities prior to backfilling. Compacted fill material in 8-inch lifts to prevent future settling. Restored landscaping to pre-excavation condition using sod replacement and mulch application. Provided homeowner with as-built drawings documenting exact pipe routing and depths for future reference. Projec
Commercial Backflow Preventer Installation: Partnering with a commercial client, I led the implementation of an advanced atmospheric vacuum breaker backflow prevention system for their new facility. This project involved a detailed site analysis, followed by a strategic installation process that prioritized regulatory adherence and long-term water safety.
Tackled blocked storm drains on Oak Street in Goldsboro after resident complaints about standing water. Used our high-pressure jetter to clear 6 street drains and connecting pipes. Removed surprising amount of debris – mostly leaves and plastic bags, but also found a kid's basketball causing major blockage! Cleared all catch basins and verified proper drainage flow. Street is now draining correctly even with today's heavy rain. Recommended quarterly maintenance schedule to city public works department to prevent future flooding issues. Residents appreciated our quick response time after recent downpours.
Backflow Preventer Installation: A commercial client reached out for assistance with installing a top-tier backflow prevention system at their new property. After a thorough evaluation, we strategically selected and installed advanced backflow preventers, ensuring that water contamination risks were minimized. This solution provides long-term protection for the property while adhering to all necessary standards and regulations.
Emergency Backflow Preventer Replacement Service: A commercial kitchen experienced a sudden failure in its backflow prevention system, jeopardizing water safety. Our team responded promptly, diagnosing irreparable damage to the preventer. We installed a new, industry-standard backflow preventer and conducted thorough testing to ensure immediate compliance with health codes. The client appreciated the swift resolution, allowing their operations to continue without extended downtime.
Backflow Prevention System Installation: A client needed a tailored backflow prevention system for their large-scale irrigation setup. After evaluating their water system’s unique requirements, I designed and installed a specialized backflow preventer with reinforced materials to handle high water pressure. This custom solution ensures their irrigation water remains free from cross-contamination while maintaining seamless operation.
Backflow Prevention System Installation: We were brought in to install a new check valve backflow prevention system for a commercial building. After careful analysis of the facility’s water flow patterns, we strategically placed the system to ensure maximum protection. Following the installation, we ran diagnostic tests to confirm the system would effectively prevent reverse flow contamination, thus maintaining the integrity of the building’s water supply.
Backflow Preventer Installation Service: We arrived at a commercial site to install a high-performance Reduced Pressure Zone (RPZ) backflow preventer. The client needed to upgrade their water infrastructure to meet current safety codes. We carefully assessed the plumbing layout, selected the ideal location for the RPZ system, and ensured proper installation to prevent potential contamination of the water supply. By adhering to strict safety guidelines and performing thorough pressure testing post-installation, we ensured the system’s reliability and the client’s compliance with regulatory standards.