1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Local Reviews
for bloomsburg, pa


Job Locations
for bloomsburg, pa

Mark B.

Mark B. Job Checkin

Commercial Kitchen Equipment Maintenance Service. Changed all filters and blower belts on rooftop units, and cleaned metal mesh filters as well. Cleaned out exhausts and pans. Cleaned all rooftop coils. Cleaned coils for the ice maker and the ice box. Cleaned coils on both food holders. Checked temps for the beer cooler and drink cooler. Both were normal. All equipment is operating normally and cleaned properly. Cleaned condensate drains to all equipment with condensate drains.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/16/23 - Found the unit with bad condenser fan motor. The motor is seized up and will have to be replaced. The unit will remain off while waiting on the part to come in. Returned to location on 3/21/23 - Installed new condenser fan motor. The unit comes on and is working properly. No further repairs are needed.


Mark B.

Mark B. Job Checkin

Arrived at location on 9/24/21 - Checked over unit found err on front speed display and front belt not running. Pulled cover and found motor not running. Turned off/on the conveyors and both started to run. Watched and found bad noise from motor. Found needs motor. Will order and return. Returned to location on 9/30/21 - Removed old motor and configured new one to match. Installed new motor and programmed control to match. Tested at speed. Found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 9/24/21 - Checked over unit found err on front speed display and front belt not running. Pulled cover and found motor not running. Turned off/on the conveyors and both started to run. Watched and found bad noise from motor. Found needs motor. Will order and return. Returned to location on 9/30/21 - Removed old motor and configured new one to match. Installed new motor and programmed control to match. Tested at speed. Found all ok at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/7/21 - Checked over unit, found motor operating. Found bushing worn and causing undue tension on shaft causing gear to free spin will order parts and return. Returned on 6/11/21 - replaced parts listed above. found shaft worn through and causing it to still slip. will need new rear shaft. will order and return. Returned on 7/7/21 - Replaced shaft, turned on let heat and verified conveyor ran smoothly with no issues. Unit is operating correctly at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/6/21 Found unit with breaker off. Checked over unit found no signs of anything shorting out or burnt up. Found 7.1 ohms on element and 120v supplied. Turned unit on found unit drawing 16.7 amps and element drawing 16.2 amps. Found blower operating correctly. Let unit heat for about ten minutes. Reassembled unit and stood upright let heat again for about 15 minutes with no issues. Unit is operating correctly with correct amp draws at this time, could not replicate issue at this time.


Service C.

Service C. Job Checkin

Removed existing garbage disposal and installed new garbage disposal. Wired in new unit, checked operation and plumbing for leaks. Unit operating normally at this time .


Service C.

Service C. Job Checkin

Found both VHL Griddle pilots not lighting intermittently. Found low MV signal from thermocouple. Removed and replaced both thermocouples. Found high gas pressure, 13" wc. Could not adjust due to regulator vent being blocked. Removed and replaced regulator and set to 4"wc per data tag. Lit pilots and checked operation, unit operating normally at this time.


Service C.

Service C. Job Checkin

Found Reach-In Cooler unit running but struggling to reach 35° setpoint. Checked over unit, found 75% blocked condenser coil filter. Removed and cleaned filter, reinstalled filter. Unit easily reached set point and cycled normally.


Service C.

Service C. Job Checkin

Found Range unit not lit, tried to light pilots found to not light, attempted to light burners found no gas. Mechanically agitated regulator and found to send gas. Replaced regulator lit pilots and burners. Unit is operating correctly at this time.


Service C.

Service C. Job Checkin

Checked over pasta cooker unit, found running per staff request watched unit until it failed, found issue is with the flame roll lit switch being faulty. will order and return. 7/12/19 Removed failed rollout switch and replaced. Noticed door was being kept open. Spoke to manager he stated since propping door open they have not had an issue. They will close door and see if new rollout switch remedies issue. If problem reoccurs we will need to I investigate excessive heat in burner area.


Service C.

Service C. Job Checkin

FryMaster service on Electric Fryer. Repair fryer and gas overhead unit. Manually check actuator and found not functioning properly and ignition failure. No power to AIF board. Replace bad fuse and AIF board for vats.


Service C.

Service C. Job Checkin

Found Frymaster Fryer-Gas unit recipe was changed. Tried to change and it would not take. Reset computer, found no change. Reset menu and had to reset computer again. Found that worked. Had to manually change selections one by one to match right side computer per manager. Only recipe not in system is chicken chalupa. Customer will need to update menu via usb. unit working at this time. ***Warranty claim rejected -- Programming is not covered under warranty***


Service C.

Service C. Job Checkin

The maintenance guys had been working on the dishwasher unit and had somethings taken apart. I checked power and I was missing a leg, so I found a bad fuse at this disconnect. The customer had a new fuse so I installed the new fuse and everything was working but the drive motor. I made the corrections on the wiring on the new contactor and overload that were installed before I showed up. The unit is running fine at this time and the maintenance will put the other things back together that they had apart before I came.


Service C.

Service C. Job Checkin

Found unit giving ignition failure. Checked unit, found bad flame sensor. Will replace Far right vat left side flame sensor. 5-17-15 Removed the left flame sensor in the car right vat and installed the new one. I checked operation and the right flame sensor was not sensing flame. I pulled it and cleaned it and checked operation. The unit is working fine at this time. **Travel Charges Billed on wo# 156194**