Arrived at location on 10/13/21 - Checked the 4th well from the left and it needs the heat light. Customer said they don’t know if it’s on or off without the light. Unit does heat. Will order and return . In service. Returned on 10/20/21 - Arrived and got ok to do work. 4th well from left. Removed the power and removed panel. Removed faulty light and installed the new heat light. Power on and unit heats and light now works allowing customer to see that it’s on. All other 5 wells ok. In service.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/15/21 - checked the c/o and tested the outlet and no voltage because the hood can't be turned on because its not wired correctly per customer. Did check the wiring in the oven and its set for single phase. Oven is 3 phase or single phase. Oven is ready to be plugged in and tested. Customer will call when everything is ready . Returned to location on 8/4/21 - Checked the c/o and have 244 vac single phase to it. Unit is 208/1. Customer is aware of the higher voltage that can cause the element to fail prematurely per vulcan. Power on and test the blower speeds and hi and low work properly. Timer times down and sound. Oven light works. Allow to heat fully and cycle and the temps are off by a little because of the voltage. Customer said she will get a temp meter to have in the oven for proper temps. Unit is ok and ready for service.


Mark B.

Mark B. Job Checkin

Arrived at location on 6/29/21 - To Install new equipment in kitchen trailer. Lifted off and set aside existing royal range from trailer. Unpacked new royal range and fryer. Assembled legs to new equipment. Lifted new royal range into trailer and hooked up gas. Moved into place and bolted front legs to floor. Moved new fryer into place and hooked up to gas. Reinstalled existing fryer, hooked up gas and bolted to floor. Turned gas supply on and bled supply lines. Lit pilots and adjusted. Test fired new fryer. Brought new royal range into service and checked oven thermostat operation. Equipment all checks okay. Lifted bain marie back into place and bolted to floor. All equipment in service.


Service C.

Service C. Job Checkin

Found Dishwasher Rinse aid pump working, sensor not detecting product, will order new sensor. 10/8/18 Installed sensor and turned unit on, pump ran in prime mode but did not pump any fluid up from bottle. Turned off and on two times and let prime but never pumped chemical from bottle, checked for clog in line, none present. Found pump tube bad (squeeze tube), will obtain and return. Unit operational but requires squeeze tubes. 10/17/18 Removed old squeeze tubes, replaced with New. Turned unit on and both wash and rinse aid primed. Ran through cycle and unit tested okay, unit operational, job complete. Both temps good


Service C.

Service C. Job Checkin

Arrived on site to repair ready access drive-thru window. Replaced cable and chain and spring, installed missing link, setup operation and checked operation - okay. Window in service


Service C.

Service C. Job Checkin

Found 2A glass fuse open on Dishwasher. Changed out with new. Turn on and saw CR1 spark and fuse opened again. Checked schematics. CR1 controls fill solenoid. Checked and found sol shorted. Changed out with new. Turn on. Now fills and heats. Customer using wash temp @ 160F. Rinse 185. Back in service.


Service C.

Service C. Job Checkin

Puddle of water under unit but no leak found anywhere inside or outside of unit. Also no popping from unit. Unit heats properly. Element okay 24 amp total. Run brew cycle. Okay. Unit refills and reheats. No leaks anywhere. No pops. All components okay. No problems found. One seal around right tank had gap in it. Used silicon to close gap.