Arrived on, 09/27/23 Dan - Arrived and found unit off and cool. Added water and turned unit on to maximum temperature. Unit stopped calling for heat before boiling water. Removed side panel to access controls. Tested high limit and found that it was not tripped. Adjusted potentiometer until unit boiled water. Unit is now good to go.


Mark B.

Mark B. Job Checkin

Arrived on, 08/22/23- Joe/Jakob - on unit, removed control-side side panel. Found chain and sprocket off of shaft. Found set screw in poor condition. Was able to mount on shaft temporarily. Costumer would like new sprocket ordered. Semi-operational. Returned on, 08/25/23- Joe/Jakob - on unit, de-energized unit and removed necessary panels. Removed old sprocket and replaced with new. Unit fully operational


Mark B.

Mark B. Job Checkin

Arrived at location on 11/10/22 - Powered unit on. Could hear the blower humming. Powered unit off and removed top panel. Removed cover over blower. Inspected bearings on blower. No slop and didn’t hear any grinding. Bearings seemed good. Lubed shaft that blower sits on and spun blower. Noise is gone. Put panels back together and powered unit on. Unit is heating without any noise. If problem returns bearings will need to be replaced. Okay.


Mark B.

Mark B. Job Checkin

Arrived at location on 2/28/22 - Examined unit, staff explained booster was spraying water from pressure relief valve. Shut off power at disconnect to the right of booster and removed front cover. Found two elements with residue on them, bottom left and bottom right. Checked elements for continuity to ground, tested direct short to ground. Found two 35a fuses blown, one for left side one for right. Water is very hard here, booster tank is most likely full of lime. Did not remove elements to check to prevent unit from being completely unusable. Called Chris, decided to order two fuses and just remove elements from heating circuit until unit can be replaced. Chris would like quote to replace and also fuses ordered and to return to remove elements from the heat circuit so unit will perform better than what it is now. Returned to location on 3/3/22 - Replaced two fuses and removed bottom left and bottom right elements from circuit. Unit working for now.


Mark B.

Mark B. Job Checkin

Arrived at location on 2/3/22 - left most well on main plate, 120v to unit 120v to element, checked amp draw, not drawing anything. Found wire burnt off terminal from limit, repaired, no amp draw. 120v @ element, element open. Infinite switch could use replacement. Will need some hi temp ring terminals but the wires look fine. Bring 1/2” shark bite for drain. Returned to location on 2/14/22 - Replaced element, switch, repaired drain pipe to well. Working okay.


Service C.

Service C. Job Checkin

removed and replaced Convection Oven relay board. reassembled and testes. unit cycling on temp. finished other call here then checked back. on at proper temp. good to go


Service C.

Service C. Job Checkin

Examined Top Oven unit. found power wire pulled out from middle switch to left. reattached wire and tested. unit heated and cycled. conveyor running slower than bottom unit. can't adjust conveyor time. customer will run unit and advise.


Service C.

Service C. Job Checkin

Upon arrival Hot Well unit was on. The water was drained and the unit was inspected. Left side overload is bad, ohmed out the heater and it was found to have 53 ohms, the same as a new one. Talked to customer and they will wait for overload. Need hi limit. Will order and return. 9/4/20 The water was drained and new high limit switch was installed. Hot well was turned on and all heaters are functioning.


Service C.

Service C. Job Checkin

Steamer Compression fitting leaking to fill solenoid, repaired, sealed, tested.


Service C.

Service C. Job Checkin

Upon arrival found 3rd hot well not heating. Found a bad high limit. Removed and replaced high limit switch. After installation the unit was tested for operation and the unit is working as expected.


Service C.

Service C. Job Checkin

Microwave Oven Unit has 1 mag that has a hole in it, catalytic converter is clogged badly, needs new door hinges, left is flexing away from switch. Note: quoting additional repairs, closing out this work order.


Service C.

Service C. Job Checkin

Examined middle hot well unit and found unit set up but not heating. Checked power to element 212V . Element needs to be replaced. Will order. 11/26/19 returned for service, removed bad element, old element was leaking water, had to cut L1 and L2 back to good wire, installed element drawing 14 amps and heating, tested good


Service C.

Service C. Job Checkin

examined Convection Oven unit. burner lights then goes out. disassembled and cleaned flame rod. also cleaned out debris from burner area. reassembled and tested. fan noisy. removed back panel and examined blower wheel. fan motor will need to be replaced at some point in then future. retested, unit lit, waited for cycle. good to go. customer asked if we could go over bottom unit. starting second work order


Service C.

Service C. Job Checkin

examined Steamer unit, found gas valve bad, got wet from steam leaks in plumbing, several leaks in heavily rusted piping drain assembly - completely rusted away all, so need new pilot assembly and ignition wire unit is not operational at this time, other problems or leaks may exist when steamer is at operating pressure, will quote customer on repairs Note: quoting additional repairs, closing out this work order.


Service C.

Service C. Job Checkin

MET Holding Cabinet reading 100 all the time, even when dry. 9/13/19 Replaced humidity sensor, tested, humidity reading correctly now.