Commercial Kitchen Equipment Repair: Addressing improper humidity levels in a proofing cabinet, I adjusted the humidity control settings. This ensures optimal conditions for proofing dough, leading to consistent baking results.


Ashley B.

Ashley B. Job Checkin

Commercial Food Warmer Repair Service. Confronted with recurrent false alarms originating from a malfunctioning sensor, I meticulously replaced the sensor with precision. This detailed service involved a thorough diagnostic examination, identification of the faulty components, and the installation of a new sensor. The result ensured not only the elimination of false alarms but also the restoration of safe and efficient performance, vital for the food warmer's designated use.


Ashley B.

Ashley B. Job Checkin

Commercial Hot Water Dispenser Installation. A client decided to upgrade its amenities by installing a brand-new commercial hot water dispenser. Our dedicated installation team arrived at the establishment, well-prepared for the task. We meticulously positioned the hot water dispenser in a convenient and accessible location within the café. Our experts then connected it to the water supply, ensuring a seamless flow of hot water at the desired temperature. To guarantee optimal performance, we fine-tuned the dispenser's settings and conducted thorough testing. Upon completion, the café had a reliable hot water dispenser ready to provide piping hot water for teas, coffees, and other beverages, elevating the quality of service for their valued customers.


Ashley B.

Ashley B. Job Checkin

Arrived at location on 5/6/21 to service steamer. Turned off to let drain and found fill valve was constantly filling. Found wired to have constant 40v to valve and will shut with breaker off. With breaker on and unit powered down it stays open and overflows generator. Will order fill valve and return. Replaced valve turned on verified no leaks, let fill and steam unit is operating correctly at this time.


Service C.

Service C. Job Checkin

found Dishwasher Pass-Through unit drained. filled and ran with tim. found issue is auto/manual switch was in the manual mode and was causing it to stay in a wash cycle. put in auto mode and found unit to run as it should.


Service C.

Service C. Job Checkin

Recovered Reach-In Cooler refrigerant. Removed failed compressor, start components and filter drier. Installed new compressor. Leak checked system. Charged system and checked operation unit operating normally at this time.


Service C.

Service C. Job Checkin

Found Oven unit not heating, looked over found 24b to module 24v to gas valve found gas pressure from valve. found no spark, replaced module turned on found to heat, cycled unit and allowed to heat to temp. Unit is operating correctly at this time.


Service C.

Service C. Job Checkin

Found Combi Oven unit not turning on, checked 5p ensure no a,p draw when powered supplied to unit found okay. Found hi limit for generator was tripped and could not be reset, found end of cap tube showed signs of being burnt or shorted out, believe tube was shorted out causing un-resetable damage to hi limit. Will order new hi limit for generator, outboard hi limit and return to replace. 8/8/19 Removed the faulty high limit and installed new. Then checked operation and the unit was calling for descaling. I pulled the water level probe and it was clean and nothing was grounded. I had some issues getting into the service manual because the dip switches were corroded. I tried resetting the descaler mode since we already descaled it but it wouldn't work. I checked the drain pump operation and it was fine. I called Rational and they had me check a few other things and found the water level probe wasn't sensing at all. I shut the unit down and water off. We will need to order parts and re


Service C.

Service C. Job Checkin

Found Dishwasher Commander unit booster heater contactor chattering. Checked voltage to contactor coil, found 24 vac then dropping to 22 vac causing contactor to chatter. Spoke with Jason at Insinger tech support. He says this is normal operation. **Travel Charges Billed on wo #184563**


Service C.

Service C. Job Checkin

When I showed up the fryer was empty so I put water in for testing. I checked thermopile readings and they were good but when the main burner came on the millvolts continued to drop until the gas valve didn't have enough power and shut off. The gas pressure was too low and when the burners came on the pilot died down and wasn't generating proper voltage. After making adjustments the millvolts stayed at 270. The unit is working fine at this time...


Service C.

Service C. Job Checkin

Found Walk-In Freezer unit with door seal badly burned. Found door heaters shorted to box wall. Disconnected door heaters so unit can be ran until door seal and heaters are replaced.


Service C.

Service C. Job Checkin

Found no power to start components on Reach-In Freezer. Found molex connector from power pak to control module burned. Will need start components and wire harness replaced. 2-5-19 Opened up the unit and checked components and I was missing the other side of the plug that was burnt That went to the start components and confessor fan motor. I spoke to tech support and he didn't want to deal with part numbers so he sent me to parts. They put me on hold and when they finally came back they said they would have to look into it and call me back. I''m waiting to hear back from the manufacturer for proper part number needed. 2-13-19 Removed failed start components and compressor power cord. Installed lower pack and power cord using cord kit. Energized unit and checked operation unit operating normally at this time.


Service C.

Service C. Job Checkin

Found Microwave unit off. Looked over unit found f8 low temp error. Entered test mode tested mags and blower found okay. Tested heaters found no amp draw. Checked solid state relay found to have voltage to it but not closing. Replaced relay turned unit on. Tested heaters found to heat. Ran product through unit Found okay. Unit is operating correctly at this time.


Service C.

Service C. Job Checkin

Found Pitco Fryer unit off. Replaced drain valve, temp probe, and high limit. Had difficulty accessing high limit due to the dried grease around it. Plugged unit in, filled with oil, allowed unit to heat to 350 degrees and ran product through unit. Found okay. Unit is operating correctly at this time.


Service C.

Service C. Job Checkin

Checked operation and the Plate Heater/Dispenser unit didn't turn on at all. I pulled it apart and found the back of the power light was cracked and also the neutral is broken somewhere in the cord. We will need to order parts and return to repair. 9-24-18 Found unit off. Found new light to be wrong part. Installed new power cord. Turned unit on, verified power to unit and found light to be working but is cracked inside. Zip tied light closed to prevent shorting out. Will reorder light to verify incorrect part. Unit is operating normally at this time. 10-19-18 Installed new light, had to modify it to work. Tested, all okay at this time.