Commercial Ice Maker Installation. A commercial client reached out to us for a new commercial ice maker installation. We assessed their needs, recommended a suitable model, and executed a seamless installation, including water supply connections and drainage setup. Testing confirmed efficient ice cube production.


Mark B.

Mark B. Job Checkin

Arrived at location on 11/15/21 - There is buildup on the top of the evaporator, distributor, and curtain causing uneven flow across the evaporator. Bridge thickness and cube formation is very uneven as a result and KoolAire machines harvest on a float which will cause it to run until all the water is used which will result in some ice being too thick and some too thin. Will return tomorrow to clean. Returned to location on 11/16/21 - Cleaned and sanitized the ice machine and bin from top to bottom. Disassembled and scrubbed as required. Discarded first batch of ice. Cube size and bridge thickness is very consistent at this time. Bridge thickness is 1/8”. Machine will take at least 24 hours to fill the bin if no ice is being used. Job complete.


Libby D.

Libby D. Job Checkin

HOSHIZAKI Ice Machine - 04/06/21- Dave-Kitchen manager said machine was not making ice and maintenance just cleaned the machine and bin. Turned machine to ice and had a low water alarm. Reset the alarm and still no water to the machine. Found water valve turned off that was feeding the filter. Turned on water and machine started to fill and make ice. Noticed water filter was last changed 12/27/19.. Machine is due for a water filter and proper cleaning after the filter is changed. Maintenance stopped by as it was running and said he still needed to deep clean the machine and asked if we could order a filter and have it shipped directly to them to change. No other issues found with the machine.


Service C.

Service C. Job Checkin

Checked out unit and found Dishwasher unit off. did not see any burnt wires so turned the power on and checked out. had to drain unit and then it filled up and ran. unit popped. so needs the wash pump and rinse tubing so will order and return. 8-24-20 Came in and installed new pump kit and rinse tube. found the plug that connects the wash pump was melted. also plug that connects drain pump was melted. cut all the burnt wires and made new terminal. had to drain the unit completely to flip the unit sideways since there was no access from the back. put the unit back together and tested, operation okay.


Service C.

Service C. Job Checkin

Found Ice Machine unit running when I arrived and dropped a batch of ice shortly thereafter, I checked unit and found to be dirty especially the evaporator which ice was sticking to, Customer approved of me cleaning unit, I cleaned and sanitized unit and ran a batch of ice and is working properly at this time


Service C.

Service C. Job Checkin

Checked the Combi Oven unit and found the generator was overfilling the combustion blower and never starting. checked and found that generator was continuously filling and the fill solenoid was energized all the time. checked inside the unit and water is coming out steam port. removed the water and cleaned them and put them back. tried the unit and it is working. generator filled up and stopped and the unit is steaming. operation okay.


Service C.

Service C. Job Checkin

Checked out Holding Cabinet unit and found that the left controller is calling for heat but controller is not closing. Ran to shop to get new controller. installed and checked operation, okay. unit is pulling 6 amps and heated up to 205 degrees and cycled off, all operation okay.


Service C.

Service C. Job Checkin

Checked out Gas Fryer unit and found that unit was showing 420 degrees on display. checked temp probe and found bad probe. will obtain and return.1= 8262212= temp probe ***Travel on WO# 180872 - 4-30-19 Returned with part. removed temp probe on left side and installed new probe. checked operation of unit. set 360, act temp 363. operation okay.


Service C.

Service C. Job Checkin

Checked out Electric Oven unit and found that the door gasket is falling apart. Called and talked to Brian at Merry Chef and got the part numbers. per Michelle qwp (Expedited Freight) parts. 9-5-18 Removed old gasket, cleaned and installed new one with sealant. sys ops okay.


Service C.

Service C. Job Checkin

Arrived onsite. inspected Reach-In Cooler unit, found evap fan motor making noise. Disassembled the motor. checked my truck stock. I don't have one, reassembled fan motor. Unit is working at this time. but fan motor needs to be replaced. Will order parts then return when parts arrive. 07/10/18 Arrived onsite. inspected unit, found evap fan motor making noise. Disassembled the motor. Checked my truck stock. I don't have one. reassembled fan motor. Unit is working at this time. but fan motor needs to be replaced. Will order parts then return when parts arrive.