Manager reports that lately, the breaker for the steam table seems to randomly trip. Checked the wires and electrical components and discovered that the wire nuts at the power cord inlet box were melted and in contact with metal, causing the breaker to trip. Made repairs and installed new porcelain wire nuts. Tested and the unit working well


Service C.

Service C. Job Checkin

Checked over Mixer unit. found wet grease on top of bowl lift gear box. investigated and found grease is breaking down and traveling upwards and coming out of top. due to over filling or breaking down. looked over parts break down and found no seal for that location. unit is operating OK at this time. **Travel Charges billed on wo# 210806**


Service C.

Service C. Job Checkin

Found leak between Oven ranges, customer not using range on left side broken union free and push range on left out of the way, removed plug from manifold in left oven and put in union and put union back onto right range - turned gas on, lit pilot, tested for leaks, were none right range is in poor condition


Service C.

Service C. Job Checkin

Examined Pizza Oven unit. found safety bad. removed and replaced safety and thermocouple. tested. pilot holding. burner lit. good to go


Service C.

Service C. Job Checkin

Replaced oven safety valve and thermocouple on back kitchen top right oven, per customers request, tested okay.


Service C.

Service C. Job Checkin

Installed new drain valve and fixed two leaks on Electric Steamer.


Service C.

Service C. Job Checkin

Found JAC Dishwasher off and filled with water. Checked elements, ohmed out, Rinse the same top and bottom, wash a little higher. Turned power on cycled unit on start filling. Shut down and drained unit. Checked water level float, found hanging up. Cleaned float and retested. Unit filled rinse heater each pulled 8 amps. Rinse came up to 185* cycled off. Wash heater cycled and pulled 13amps cycled off at 185*. Ran unit thru 7 cycles. Pressure display stuck at 100 psi. Water levels held and temps held.