Mark B.

Mark B. Job Checkin

Arrived at location on 7/13/22 - spoke to Shavit about braising pan. Unit will not stay lit. Upon initial inspection, found unit to be in poor shape. Hi limit and operating thermostat probes are both corroded. Upon removal of hsi and flame sensor, found hsi to be broken and flame sensor completely corroded. Thermostat housing was hanging loose banging off the side of the unit. Corrected this by drilling housing and securing to bracket with new hardware. Also modified bracket position so housing no longer bangs off anything during operation. Will order all defective components. Spoke to Larry about repair cost potential and he gave me permission to order what was needed to rectify this unit to its former glory. Unit out of service. Returned to location on 7/19/22 - Disassembly was very difficult being hindered by heavy corrosion and layers of dried grease. Installed new components and reassembled. Tested. Had to reposition flame sensor slightly. Unit back in service.


Mark B.

Mark B. Job Checkin

Arrived at location on 3/30/22 - Unit has bad draw off valve stem unit is operational but requires part. Returned to location on 4/11/22 - Removed draw off valve assembly from right kettle. Had hard time removing draw off stem from retainer. Installed new stem. Put some grease on threads. Installed onto fight kettle. Had a hard time tightening the stem. Stem is very hard to turn. Spoke to Larry. Said to order a new retainer. Will obtain new and return. Must call Larry for return. Larry said not to QWP but needs it by 04/29/22. Returned to location on 4/13/22 - Arrived to location and spoke to maintenance personnel. Disassembled stem from retainer and installed new. Reassembled in unit and tested fit and function. Unit is back service.


Service C.

Service C. Job Checkin

Checked middle Fryer unit, found pilot corroded and not putting out good flame. Thermopile has enough mv to keep pilot lit but not open valve. heated t pile and burner came on. tried to clean pilot but it in to bad of shape. turned off t stat and back on 15 times and burner came on. will obtain parts and return. semi operational requires part. 3/9/21 Removed burner assembly took gas line off pilot and loosened union. dropped assembly, replaced pilot with new. put back together and calibrated to 350 set at 350. was 18 degrees cold. unit is operational job complete.


Service C.

Service C. Job Checkin

checked bottom oven and customer said it will stop heating and the temp display goes to all 0's. Power on from a cold start and the display did go from 325 to all 000 but went back to 325. Burners come on and it heats. Moving the control panel cause the temp display to go to 0 briefly. The time display is not affected . Temp control is acting up. Called SOUTHBEND and talked to Charles and he said it needs a new control. Got part and price. Ok order the part per Curt. 9/27/19 Removed faulty temp control and installed new temp control board . Power on and unit heats to set point @ 350° F and cycled it 3 times and temp calibration is ok. Unit did not fail. Back in service


Service C.

Service C. Job Checkin

Checked out Turbo Chef oven in last run lounge. Powered on unit and let heat, unit heated to set temp, after heating, display read f4 error, door switch display read close door when door was closed. Let unit cool, removed side panel. Checked switches, both are working properly. Adjusted switches so were aligned properly. Powered back on, unit heated to set temp. Ran product, product came out good, no errors. Opened and closed door numerous times, no errors. Unit is back in service.


Service C.

Service C. Job Checkin

Checked out 2 drawer warming cabinet. powered on unit. display lights. no heat. checked and have 121 volts incoming to unit. disconnected elements and tested. have continuity through both top and bottom elements. checked ohms and have 35 ohms on both elements. called star and spoke to J.R. found that controller is bad. got part number for controller from J.R. customer wants a price on controller. got price from Harrisburg. customer approves of price. Will order through shop and return to install. 1/3/19 Unit was not in cafe where it was last trip. customer moved to outside storage unit. found unit. opened up. removed probe and faulty controller. replaced with new and wired. attached probe to cavity. reassembled. plugged unit in. unit heated. have proper amp draw. let run to set temp. reached set temp. customer moved unit back into building. unit is back in service


Service C.

Service C. Job Checkin

Turned on. The fan does not spin. Power to motor. Need new. Part # 419720-2. 115v/single phase. $793.40. Wheel 415780-3 $129.10. Joe said okay to order. Will obtain and return. 6/28/18 Removed old motor. Cut off the wheel to remove mounting brackets. Installed new motor and wheel. Turned on. Motor spins okay. Back in Service.


Service C.

Service C. Job Checkin

Found when testing millivolts on thermopile it was very sporatic. Customer said pilot would go out when t-stat was turned on. Changed t-pile and took mV. Stayed strong and above 300 mV. Used truck stock. Unit in use.