1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Local Reviews
for lansdale, pa


Job Locations
for lansdale, pa

Mark B.

Mark B. Job Checkin

Arrived at location on 7/20/21 - spoke with Viktor about issues with unit. First issue was the large discharge pump in back of unit was leaking at the flange. Viktor was not very concerned about the constant drip there. Second leak was very heavy coming from half way up the back of unit at the lower spray arm. Viktor wanted this fixed. Called Danny from manufacturer and he recommended disconnecting and pulling unit out and replacing the gaskets. This would require major tear down of plumbing and ventilation of unit and equipment to move out the large machine. I took many pictures of unit from different angles. For short term repair I removed nut from spray arm and put silicone around it then tightened nut back up. Recommended they follow manufacturer guidelines to let the silicone set up but that will take 24 hours of downtime. Viktor would like to wait and see if unit leaks now after repair and will call if he wants further service. Unit is back in service when it cures.


Service C.

Service C. Job Checkin

Started the Dishwasher and let run. Final rinse starts at 188 ° and rinse pressure is 25 psi. Ran many trays through and okay. Temps okay. The drain sol valve is not working and is disconnected. one rinse arm is not working . Checked the pump motor and it''s spinning, Open and cleared out the piping to the pump and from the pump into the spray arms and the nozzles are open. Tested several times and still won't pump. Need pump and drain valve and the lock wash pins for the spray arms. The unit is in service and wash temps are okay. PER VIKTOR, QWP (expedited freight) ALL PARTS 12/13/18 Disassembled and removed old pretense pump and installed the new pump and wired it in . Zip tie in wires and head butt end terminals . Removed and installed the new drain valve and installed the 2 new wash arm blocks. Power on and let heat up and run cycles. Customer passing many dishes through unit and temps are good. pre wash is running and at 139F wash is 164°F pre rinse is 156 ° F and final rinse i


Service Check-In ..

Service Check-In .. Job Checkin

Blodgett commercial kitchen equipment repair service.


Service C.

Service C. Job Checkin

Pump shaft seal leaking. Motor badly rusted. Will order complete pump assembly. - Replaced wash pump and motor. New gasket leaked. Swapped with old rubber gasket. No leaks at pump. Note- small drip at conveyor bearing gasket bulkhead warped cannot tighten further. Unit operational.