Arrived on, 8-17-23- Sam S-Checked freezer, neither of the evap fans are running. Not getting power to either fan. Ordered digital controller and both door switches that were sticking. Freed up switches for the time being. Returned on, 8-29-23 Sam S-Installed new controller and door switches. Confirmed fans run now. Checked cooling and defrost all ok.


Mark B.

Mark B. Job Checkin

Arrived at location on 1/27/22 - Checked over unit. Found blower runs rough. Customer is going to take care of it at a later time. Watched unit run found some loose wires causing unit to lose 24v. Repaired wires and ran unit. Found unit runs at this time.


Service Check-In ..

Service Check-In .. Job Checkin

Commercial deep fryer repair service on Frymaster gas fryer.


Service C.

Service C. Job Checkin

Checked over Top Oven unit, found gas valve sticks open. replaced with truck stock and tested, okay at this time. **No Travel Charges per Service Manager**


Service C.

Service C. Job Checkin

Frymaster service repair on gas fryer. Check pilot staying lit and voltage. Clean and perform maintenance.


Service C.

Service C. Job Checkin

Turned Oven unit on and let heat found temp control would adjust to random temperatures. Will order new temp board, probe and knob and return to replace. 6/12/19 Removed the faulty stat, probe and knob then installed new. Then programmed the unit and checked calibration to adjust as needed. The unit is maintaining temperature fine but both cooling fans are supplied with 120v but are not working and need replaced. We will need to order and return to replace. 7/5/19 Removed failed cooling fans, replaced fans, energized and checked operation unit operating normally at this time.


Service C.

Service C. Job Checkin

I lit the Gas Fryer pilot and fired the unit up to check operation. The unit shut off at set point and the pilot stayed lit. I checked while the unit was running and I had a 170mv drop across the stat. I took the connections apart and cleaned everything up and that took care of the large voltage drop. The gas valve was on the edge of not having enough voltage to stay open. The unit is working fine at this time. **Travel Charges Billed on wo# 180591**


Service C.

Service C. Job Checkin

Found noise coming from convection Oven fan motor. Found burned wire on motor repaired wire. Will need new motor. 4/30/19 Pulled unit apart and removed the faulty motor then installed new. I checked operation and the unit is working fine at this time..


Service C.

Service C. Job Checkin

checked Oven operation and the fan wouldn't come on in low but would try in high (No capacitor present). The motor and switch need replaced and we can try to get blower wheel off and re-use. The customer would like a quote to install the new parts and one for a completely new oven. 12-28-18 Removed back panel and attempted to remove fan blade had to cut shaft. Installed and wired in new motor and installed fan blade. Installed new speed switch. Turned unit on checked operation of motor and switch found okay. Unit is operating at this time.


Service C.

Service C. Job Checkin

Checked over Combi Oven unit, found will not ignite. Found issue due to bad hot surface ignitor and flame sensor. Will replace both. 8-10-18 Found unit in operation, let customer finish with it. Replaced hot surface ignitor and flame sensor, turned unit on. Unit heated normally. Unit is running okay at this time.


Service C.

Service C. Job Checkin

The unit was at 45 degrees and the staff said they had adjusted the stat multiple times because it was above 50 degrees. I pulled the unit out and removed the back and the condenser was plugged. I brushed and cleaned it with dirt blaster They ran the unit and adjusted it multiple times to get it to shut off at 34 degrees. I told the staff to let it run for a day and check temp before putting product back in.


Service C.

Service C. Job Checkin

Found power switch on Oven unit not locking into on position. Removed switch and cleaned but intermittently fails to lock on. Will need switch ordered and replaced. 4-13-18 Removed failed power switch. Installed and wired new switch. Energized and checked operations. **Travel Charges Billed on WO# 154219**


Service C.

Service C. Job Checkin

Found SBR Oven Range door spring retainer bracket loose. Tightened bracket and reassembled door spring assembly. Door operating normally at this time.


Service C.

Service C. Job Checkin

Found reach-In Freezer unit with temp. control set to coldest setting. Unit was freezing coil and not defrosting properly causing high temp. Set temp. control to correct position ( 4 on dial), unit cycles normally at 0°F.


Service C.

Service C. Job Checkin

Found unit off. Griddle burner valves need replaced, not lighting properly. Unable to measure gas pressure but unit may need regulator. Oven valve also needs replaced. Will order and return. 3/30/17 replaced regulator and locally purchased nipples. Unit needs t-stat, flange, and knob. Will order and return. 4/7/17 found unit off. Removed center t-stat, found the tee and supply lines both need to be removed behind manifold so they t-stat would fit. Installed new, turned on, calibrated, cycling at 350*