1833 North Cameron Street
Harrisburg, PA 17103
(717) 236-9039

Job Locations
for lock haven, pa


Map of Lock Haven PA
Service C.

Service C.


Job Checkin

Arrived, spoke to manager, said CHA Dishwasher wash rinse display was not displaying, final rinse displaying temp but when they run their sensor displays different temp, rollers on conveyor some are bad and left hand spray nozzle not working fully on wash table. Checked thermistors for wash and rinse found okay up to display board found 24v to board but not displaying. Will order digital temp display. Ran unit temped final rinse, display showed 186 degrees and thermistor resistance showing about 1070 ohms which matches per resistance chart, believe thermostat short cycling will order and replace. Checked over rollers found multiple rollers damaged but not preventing proper operation, manager said to wait to replace. Checked left hand spray nozzle on wash table found valve partially opening allowing some water but not full flow. Will order solenoid and replace. Will send quote for repairs.