Arrived at location on 4/18/22 - Arrived to location and spoke to Mike. He wanted me to swap out the current unit with another unit he had on hand. I confirmed that both units were 208/1 vac. I swapped the electrical plug and plumbing lines and allowed unit to fill. Unit heated up and Mike was satisfied with its performance. Unit in service.
Arrived at location on 8/2/21 - Spoke to owner. Checked unit out and found that all pilots were clogged. Removed pilot assemblies and removed restrictions in the lines. Fired unit up and adjusted pilots. Unit back in service.
Found sandwich prep table Drain line clogged. Cleared drain and routed for better drainage.
Checked GLO Slicer unit, lots of play in blade and plate on top of blade cracked . Should replace entire hub assembly , will obtain and return.