Arrived at location on 6/25/21 to repair Southbend Kettle. Removed failed secondary low water cutoff and replaced. Energized and checked operations. Found no power to low water cutoff. Checked over unit, found wire broken off terminal in primary low water cutoff. Repaired wire, energized and checked operations unit operating normally at this time.