Arrived at location on 7/24/21 - examined unit, pilot holds for a short while then goes out. Thermocouple burnt up, safety is newer, replaced thermocouple with robertshaw 18" and tested. Pilot could be in better shape but its working. Unit heats and goes into bypass.