Ashley B.

Ashley B. Job Checkin

Commercial Kitchen Equipment Repair: Dealing with clogged spigots in juice dispensers, I cleaned and cleared them of debris. This maintenance task ensures smooth and controlled juice dispensing, enhancing customer satisfaction.


Ashley B.

Ashley B. Job Checkin

Commercial Kitchen Appliance Repair Service: Responding to concerns about temperature fluctuations in a commercial fryer, I executed a precise thermostat calibration. This service guarantees accurate and consistent frying temperatures, ensuring the quality of fried products.


Ashley B.

Ashley B. Job Checkin

Commercial Convection Oven Installation. With expert precision, I installed a commercial convection oven, ensuring that the electrical connections were secure and the oven's temperature settings were calibrated to perfection. This meticulous installation guaranteed consistently impeccable baking results for the bakery's operations.


Ashley B.

Ashley B. Job Checkin

Commercial Kitchen Appliance Maintenance Service. We visited the client's location to conduct maintenance on the kitchen appliances in the business. Our process included inspecting each appliance, ensuring proper operation, cleaning the condenser coils in the freezer and refrigerator units, checking hinges and gaskets on appliance doors for proper closure, and thoroughly cleaning to remove grease build-up. Finally, we replaced filters in each kitchen appliance to ensure ongoing cleanliness and efficiency.


Ashley B.

Ashley B. Job Checkin

Commercial Pizza Oven Installation. Assisting a new pizzeria, we undertook a precise installation of their commercial pizza oven. We positioned the oven, secured gas and electrical connections, and conducted tests to ensure proper baking temperatures. The pizzeria owner was pleased with the swift installation of their fully functional oven.


Mark B.

Mark B. Job Checkin

Arrived at location on 8/8/22 - Found box temp at 29F, evaporator fans are running and coil is clear. Made rooftop access, checked condenser unit, found cycling off from high head pressure. Coil has spiders all over and tree seed pods and pollen stuck in the webs and causing low airflow. Cleaned off and chemically cleaned. Checked and box is now at 6F, confirmed unit working correctly at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 7/12/22 - Checked over unit, found nothing visibly wrong, put bags in and ran, unit pulled vacuum and sealed normally, repeated 2 more times. Spoke with kitchen manager, said that it seals but bags aren’t keeping vacuum. Put a wrench in bag and sealed on left side, let sit, both are holding, checked original bags and found some had lost vacuum. On closer inspection of bag it appears that they may have small punctures. Looked at unsealed bags and found a few more like that. Recommend keeping new bags in an area where they won’t be damaged.


Mark B.

Mark B. Job Checkin

Arrived to location on 1/24/22 - Spoke to customer was told they replaced motor timer but it may not be wired correctly. Called manufacturer to get wire diagram. Found timer was wired incorrectly. Rewired and checked operations. Unit operating normally at this time.


Mark B.

Mark B. Job Checkin

Arrived at location on 8/3/21 - Removed failed condenser fan motor and fan blade and replaced. Energized and checked operations unit operating normally at this time.


Service C.

Service C. Job Checkin

Checked over Reach-In Freezer unit, found door gasket damaged causing ice buildup in freezer. will order new gasket and return to install. 6/8/2020 Removed damaged gasket, installed new door gasket, tested operations, confirmed unit working correctly at this time **Travel Charges Billed on wo#205729**


Service C.

Service C. Job Checkin

No power to hot well - Found 120V incoming, no amp draw at heating element, heating element failed continuity check, heating element has failed and will need to be replaced, will quote.


Service C.

Service C. Job Checkin

checked over Dishwasher unit, found same fuse blown. traced all wires associated with that fuse. found water in pre-wash float box. found coming from drip/leak in table attached to unit. advised maintenance to repair table and add a leg in its place on table. drained electrical box and repaired damaged wire and tested okay. closed up unit and advised maintenance I left float box open so it will not fill up again and that they will need to close up after leak is resolved. will order float and replace due to possible unforeseen issues it may have to being shorted out numerous times. looked up part number and found it is no longer available.


Service C.

Service C. Job Checkin

Found Proofer water inlet hose pulled out of compression fitting. Removed side panel, Pushed hose back through rear of unit and reinstalled in fitting. energized unit and checked operation unit operating normally at this time.


Service C.

Service C. Job Checkin

Checked over Blended Ice Machine unit. found display blank with a line through the center. upon checking found all connections okay. will need to order display. 9/27/19 Replaced display and preformed update and got new menu emailed and uploaded. tested unit and found will need calibration. found customers scale did not work and they will calibrate it when they get scale working. unit functional at this time.


Service C.

Service C. Job Checkin

Found Grill unit not heating when switch is turned on. Looked over unit found wire was pulled out of wire nut attached wire and taped wire nuts so wires wont come out again. Turned on and found unit to heat, let unit heat. Unit is operating correctly at this time.