Per customer Range unit is not firing, found pilot lit mill volts reading 95 mv pilot weak shut pilot off clean pilot assembly and retested - still only getting 95 mv replaced thermopile and tested millvolts reading 400 mv pilot only 300 mv main burner on, tested valve is dropping out when millvolts removed, unit came up to set temp