Job Checkin

Unit cuts out to reset with both compartments running. Not kicking out on low water. Called Groen and spoke to Gabe who thinks its relay. Also, drain box is leaking. Cavity hoses will need replacing. Will order parts. 3/24/17 Returned and replaced drain box. Had to take flu cover and flu back off unit to get to hoses. Replaced cavity hoses. Relay sent was different brand than what was in unit. Had to figure out where wires went. Ran unit up to steam . Unit cuts out when you use both compartments. Took video of it. Going to send to Groen. 4/3/17 Tried jumping pressure switch. No change. Called Groen and spoke to Steve White. He said remove probes and see if hole in baffle is open on each probe section. Poked a pick in them. Reassembled and tried unit. Ran 4 cycles with both compartments on. Unit did not kick out. Needs deliming. Drain valve does not work. Maintenance is going to work on it.