checked Fryer unit, pulled top of solenoid coil and removed wire nuts. put in cycle and tested voltage at coil. had 24.6 volts. unit heated for awhile then gave E92 error. called henny penny mark said is solenoid valve. pull apart and clean. told him it's leaking grease from stem and valve body at bottom of stem. he suggested to replace. gave me part number for replacement part. unit is operational but not in pressure menu. requires part. unit can be pulled from line and taken to back. Amanda wants part Q.W.P. 10/22/20 Removed old valve and replaced with new one. tested for leaks while cooking. ran unit thru a pressure cook and got no errors ,no leaks present. unit is operational job complete.