I had a situation over the weekend with no heat and 30 degree temperatures outside. Jeff was able to respond quickly and explained the problem and it was fixed within 30 minutes or so. I highly recommend Classic Aire Care.
John is always on time and allows me to be engaged with the process which builds confidence and in my opinion adds value to what I pay each year.
Thanks to Jeff I had not only great service but a special accommodation since I am a disabled United States Marine from Korea Jeff was great in explaining the questions that I had and I was well satisfied with the service
Technician was obviously knowledgeable courteous and in my opinion did a great job However I strongly believe that a discount should be given to veterans especially those that are disabled this is definitely a tiebreaker
John Murphy is my regular tech and knows my very complicated system and I trust him and Classic to provide honest and technically service.
John was very helpful in pointing out things that I needed to do to have a better operating system. I appreciated his help and knowledge.
Thank you Roger for cleaning up my furnace and explaining some issues I was having. He arrived within the timeframe provided.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 3.8A . Inducer: 1.8A. Gas pressure: 3.5 inches water column. Temperature rise: 68 . Supply: 133. Return: 65 . Adjust blower.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Found run capacitor weak: 22%low. Replaced capacitor and tested amp draw. Checked filter. Checked combustion zone: good. Customer removed door to basement to balance pressure. Blower: 4.9A . Inducer: 1.4A . Gas pressure: 3.4 inches water column. Temperature rise: 57 . Supply: 126 . Return: 69 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filters. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 8.6A . Inducer: 1.4A . Abj Gas pressure: 3.6 inches water column. Temperature rise: 51 . Supply: 71 . Return: 122.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Customer declined humidifier service. Blower: 2.5/3.2A . Inducer: 0.07/1.2A . Gas pressure: 1.9/3.5 inches water column. Temperature rise: stg1: 43 . Supply: 115 . Return: 72 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Replaced air filter. Blower: 2.9/3.7A . Inducer: .07/.22A. Gas pressure: 2.7/3.9 inches water column. Temperature rise: 55 . Supply: stg2: 134 . Return: 79 .
Fall maintenance today for both home furnaces! Renewed maintenance plan today!
Cleaned and checked gas furnace. Inspected heat exchanger & flue venting. Checked voltage & amp draw of motors. Checked filter. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 3.2A . Inducer: 1.03A . Gas pressure: 3.4 inches water column. Temperature rise: 53 . Supply: 130 . Return: 77 . Basement pressure is negative due to leaks in return air ducts: -.011” water column. Recommend sealing return duct leaks.
cleaned & checked Condensing gas furnace. Inspected heat exchanger & flue venting. Cleaned burners & flame sensor. Checked filter. Checked drain. Checked voltage & amp draw of motors. Clean and check humidifier, replace pad, checked water flow and drain. Blower: 6.2A . Inducer: 1.76A . Gas pressure: 3.4inches water column. Temperature rise: 57 . Supply: 133 . Return: 76 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 5.1A . Inducer: 1.66A . Gas pressure: 3.4 inches water column. Temperature rise: 52 . Supply: 127 . Return: 75.
Emergency no heat! Found furnace ignitor cracked! Replaced with new universal and now heating. Good to go
October 7, 2018. Returned and replaced inducer assembly. Clean up debris from gasket material. Tested operation. Inducer: 1.7A. Check temperature rise.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 5.1A . Inducer: 1.65A . Gas pressure: 3.4 inches water column. Temperature rise: 51 . Supply: 126 . Return: 75 . I found inducer motor Noisey. Amp draw is OK. Motor may or may not fail this winter.
Found inducer motor has bad connector. Also inducer motor bearings were very loud. I installed a wire tie to make connection for temporary heat. Work suggested work suggested: Replace draft inducer assembly: $535. Customer paid $150 down today.
Fall maintenance today for both furnaces! Changed filters and humidifier pad