Like the new option of them letting you know by email they are coming. He was here a little after 8 so he was on time for an 8-9 appointment. Spent time cleaning my outside unit. Very nice man.
Always happy with your service. Love the text sent prior to your arrival
Technician arrived in the time slot did a good job was very friendly. No issues at all.
Have been with Classic Aire Care for many years and they have always provided excellent service.
Nice looking service vehicles . Technicians were professional felt like I got an honest servicing on the HVAC system
My home is now 2 years old. The Builder’s HVAC Contractor went out of business shortly after I purchased my new home. Classic Aire took over the original HVAC Contractor’s clients not quite 2 yrs ago. I have been a customer of Classic Aire Care for that same period off time. This has been a fantastic experience. Each of their Service Techs and their Office Staff have been nothing but customer oriented and will to do what ever it takes! I strongly recommend you consider signing up for their annual service agreement.
Our experience with Classic Air Service was top notch your service man Jeff Kelly arrived ready and prepared to solve our heating problem, with his back pack and necessary tools to work with. He wasted no time and set out to solve our problem and inform us of the problem. He explained it and the cure and how it was working and how to fix it. No fuss no maybe,s , he gave us a price which was fair and reasonable no unnessiary add on,s. Thanks to him and you company I would highly rercommend Classic Air Care to everyone.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Blower: 2.7A. Inducer: 0.6A . Adjust Gas pressure: 3.5 inches water column. Checked temperature rise. 59. Checked filter. Supply: 135. Return: 76.
I replaced warranty humidifier control. Rewired humidifier system for updated control. I found furnace temperature rise out of range! Found air filter clogged (1” pressure drop) due to use of cool mist atomizing humidifiers in the home. Explained operation of new control to customer. Current humidity: 34%. Ambient: -2. Moisture on windows. Suggestions: expect lower humidity in extremely cold weather. Air is currently at maximum humidity due to ambient conditions. Set blower activation switch on humidifier control to “on“ for maximum humidification. Consider dialing down humidifier control and extremely cold weather.
Cleaned & checked condensing gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. UV lamp for APCO air purifier is past due for replacement. Customer declined. Customer services humidifier. Blower: adj:7.3A . Inducer: 2.15A. Gas pressure: 3.2 inches water column. Temperature rise: 65 . Supply: 139 . Return: 74 .
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Checked filter. Blower: 4.7A . Inducer: 1.0A . Adjust Gas pressure: 3.6 inches water column. Temperature rise: 52 . Supply: 125 . Return: 73. Found a bad wire connection at humidistat. Corrected and tested operation. OK. Clean and check humidifier, replace pad, checked water flow and drain.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Replaced air filter. Test capacitor. Found blower run capacitor weak: 13%low. I checked warranty status through Lennox pros.com: 5 year warranty. Part is out of warranty. Replaced capacitor and tested amp draw. Blower: 3.9A . Inducer: 1.1A . Gas pressure: 3.4inches water column. Temperature rise: . Supply: . Return: . Suggestions: replace thermostat batteries.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked filter. Checked voltage & amp draw of motors. Test capacitor. Found run capacitor weak: 13%low. Replaced capacitor under parts only warranty and tested amp draw. Blower: 4.5A . Inducer: 1.0A . Adj Gas pressure: 3.5 inches water column. Temperature rise: Z1Only:56. Clean and check humidifier, replace pad, checked water flow and drain.
Cleaned & checked 2 gas furnaces. Inspected heat exchanger & flue venting. cleaned burners & flame sensors. Checked voltage & amp draw of motors. Test capacitors. Tested thermostat batteries. Checked filter. First floor system: Blower: 5.1A . Inducer: 1.13A. Gas pressure: 3.5 inches water column. Temperature rise: 54 . Supply: 131 . Return: 78. Second floor system: Blower: 3.9A . Inducer: 0.73A . Gas pressure: 3.5 inches water column. Temperature rise: 59 . Supply: 126. Return: 76 . Suggestions: Replace air filters. replace second floor thermostat: $234 PMA price.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced thermostat batteries. Checked filter. Blower: 4.2A . Inducer: 1.02A. Gas pressure: 3.6 inches water column. Clean and check humidifier, replace pad, checked water flow and drain.
I found furnace control board bad. Fan control circuitry failure. I replaced furnace control board. Tested cooling operation. Supply: 51. Return: 72. Blower: 3.2A.
Clean and check humidifier, replace pad, checked water flow and drain. Set himidistat to 35.
Cleaned & checked gas furnace. Inspected heat exchanger & flue venting. cleaned burners & flame sensor. Checked voltage & amp draw of motors. Test capacitor. Replaced air filter. Blower: 3.1A, adj. C: 2.8A. Inducer: 1.07A . Gas pressure: 3.07 inches water column. Set up air conditioning maintenance for April.
Bedroom system: 9369: Found system low on Freon! Freon appears to be leaking at suction line near condensing unit. I charge unit for temporary cooling. Work suggested: bedroom system: 9369: Need to locate and repair Freon leak.
Cleaned and checked air conditioner and check electric furnace. Tested heating elements. Tested sequencers. Checked voltage & amp draw of blower. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked filter. Compressor: 15.1A . ambient:90 . liquid line: 120, dirty . suction line: 42 . metering device: piston . Return air: 74.5 . supply air: 54.5. Heat strips: 4.6A.
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Cleaned condenser coil. Checked filter. Compressor: 7.2A . Condenser fan:0.64,dirty . Blower: ramp:b, 5.3A . ambient: 75 . liquid line: 78. suction line: 58 . metering device: TXV . Suction pressure:123(42) . head pressure: 255(85) . Return air: 72 . supply air: 53 . wet bulb: 60 .
Cleaned and checked air conditioner. Checked drain. Checked voltage and amperage draw of motors. Tested capacitors. Checked Freon level. Checked filter. Compressor: 11.45A. Condenser fan: 1.0A. ambient: 75. liquid line: 85 . suction line:53 . metering device: TXV . Return air: 72.5 . supply air: 52.5 . wet bulb: 59. Back-flushed grass from condenser coil with Water-Saber.