Trey M.

Trey M. Job Checkin

During my inspection today, the customer greeted me at the front door. They allowed me to come inside and they showed me around to all the equipment. They showed me the air filter(s). It was a 12 x 20. They then showed me the thermostat. It was a Honeywell Nonprogrammable. They then showed me the indoor unit and the outdoor unit. I got started by turning the system off at the thermostat and made my way to the air handler. I inspected multiple different components on the system, including the blower wheel/motor, evaporator coil, drain line, ductwork, electrical connections/components, etc. I checked all of these components for proper operation and cleanliness. As well as to make sure that nothing was damaged. I made my way to the outdoor unit. On the outdoor unit I inspected multiple different components as well, including electrical connections/components, Condenser fan motor, Compressor, Motor amp draws, Refrigerant pressures(good), And the outdoor unit coil(clean). Other technica


Mike  M.

Mike M. Job Checkin

Arrive to the customers home and greeted them at the front door. Talked with the customer about the issue they were experiencing at this time. Explain what the previous technician did and what the system is doing now began troubleshooting system found compressor, not starting after diagnostics determine start relay and start capacitor have failed Used a hard start temporarily to confirm operation and no other issues present ordered parts with train gave PO. Customer not interested in membership went with repairs only. Left hard start on to give customer temporary ac while waiting on parts. Returned to service


Cameron S.

Cameron S. Job Checkin

. Inspected indoor unit. Filter is a little dirty. The coil is clean. No leaks on the coil. Blower is clean. The indoor is clean. Went to outdoor unit. Found. The compressor not running. Found the wire for the capacitor broke at the connection. Put new wire connection on. Started system. Compressor came on. It is amping in range. The system is now working properly at this time. Cleaned condenser coil.


Trey M.

Trey M. Job Checkin

when we arrived at the customers House she greeted us a the door. She walked us through her system and we started at the indoor. The blower wheel was slightly dusty, so we cleaned it. The coil was clean. The blower motor was pulling .78A. Inspected the drain line, it is clean at this time. All wiring connections are right and secure. The refrigerant pressures were 102/227. The outdoor coil was super dirty, we cleaned it and it has proper airflow at this time. The capacitor is within range per manufacturer specifications. The contractor is not showing any signs of pitting. The filters for this system are clean at this time. We will be returning on Tuesday to install a UV photomax. At this time the system is running properly according to manufacturer specifications.


Loving Air Inc. .

Loving Air Inc. . Job Checkin

The heat elements were pulling 19.91A. The indoor blower motor was amped at .72A, and clean free of debris. The indoor coil is clean at this time. We conducted a leak search and it all checked out, no leaks. The compressor is amped at 3.98A. The condenser fan is pulling .55A. The condenser coil is clean. The run capacitor is in correct range per manufacturer specifications. The defrost cycle is working properly at this time. All wiring is tight and in good condition. The refrigerant pressures were 76/375, this is within manufacturer specifications. The ductwork is clean at this time. Upon inspection of the contactor we found it to be pitted, recommended replacing the Contactor before failure. The system is working properly at this time. The customer signed for the Contactor replacement. We replaced the Contactor and tested operation.


James M.

James M. Job Checkin

Upon arrival found drain line clogged again. Went outside, and found snake hanging around drain line. Showed and explained to customer that the snake could be getting inside and clogging the drain. We do not carry a small enough screen to keep small snakes out. Cleared drain line out and explained to customer they need to cover the drain so this stops happening. Again we can run a drain line out the sofet, and a price has been made. This is not a callback. Tried to call him(the husband) to get credit card and could not get ahold of him, we will need to call him again to get payment. Explained to wife if this does this again we will need to run the new drain line.


James M.

James M. Job Checkin

Upon arrival spoke to customer, he had checked stat to make sure stat was ok. Went to attic and found drain line had clogged up. Safety had shut down system, cleaned drain line and system started up. Indoor unit in working good, blower amped at .9amps. Went outside, wires all tight. Motors working good. Pressures are 128/347, 8° subcool. System is working properly at this time of service.


Loving Air Inc. .

Loving Air Inc. . Job Checkin

Arrive to the home knocked on the front door and customer greeted me at the front door. Customer stated that the system was blowing proper airflow but that the outdoor unit fan was not cutting on. Customer has stated that he had been getting it to kick on by bumping it with a screwdriver through the top of the unit and it was working for a while but then it eventually failed. I then asked to see where the indoor and outdoor units were located. Indoor unit Took an amp draw of indoor fan motor of 1.13 which is in range per manufacture specs. Examine indoor evaporator coil and blower wheel both are clean and free of debris at this time. Examined easy trap condensate drain and is clean and free of debris at this time. Check all high and level just wiring and is in good shape at this time. Examined ductwork and is in good shape of this time. Outdoor unit Arrived at outdoor unit and found that the contactor was pulled in but the system was not running. I didn’t check the 35/5 capacito


James M.

James M. Job Checkin

Upon arrival started with indoor. Stat was set to cool, went into attic, coil is showing no signs of leaks. Blower is clear, coil is clear. Drain line needs to be cleaned out, small water inside of pan. Wires all tight. System has two drain safety’s. Went outside, system was off due low pressures switch. Found suction valve leaking finished leak searching outdoor unit, found no other leaks. Wires are all tight. System turns over when contacter pushed in. Megohmed compressor and it is green. Called east coast and found system was never registered for warranty. Priced up just repairs, and priced up cleanings and repairs with membership. Customer approved repairs, need to call east coast and order suction valve, customer will pay in full when we return


James M.

James M. Job Checkin

Upon arrival spoke with customer and went to indoor unit. Pulled door off found no leaks on indoor coil, blower amped at 1.1amps. Coil was ice cold but felt hot on duct. Found white wire was getting call from state. Looked at stat and it is set up correctly. Explained to customer that the thermostat was bad. Also noticed no safety’s in system, priced up new stat, new safety’s, and also to pull white wire at unit so heat will stop. Customer explained he is going to fix it him self. System is working but not correct at this time.