1500 N Texas Ave
Odessa, TX 79761
432-580-6342

Our Top Cities


Local Reviews
for gardendale, tx

Rated 5.0 out of 5 stars based on 4 customer reviews

Excellent service!

Erik was so professional and thorough. He explained everything in detail. He’s such a nice young man!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!!

Very professional!


Response from Mega Care Solutions:

We thank you for sharing your positive experience. It made our day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Very professional!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for gardendale, tx

joshua.megacare@gmail.com

joshua.megacare@gmail.com Job Checkin

Let the customer know I didn’t feel comfortable replacing condenser fan motor in the rain. Also contactor got wet and started to spark so I stopped working on it. Customer wants to schedule for Thursday after 4. Has an r-22 as well so it could possibly need replacement.


Erik R.

Erik R. Job Checkin

Completed cooling tune ups for both upstairs & downstairs, everything looked good to go on the upstairs unit. The downstairs had pressures/temperatures reading lower than normal. Couldn’t see any oil stains on the condenser but when I checked the evaporator coil it had a dark black spot on the edge of the coil. Took pictures & showed the customer & mentioned they don’t make coils for R-22 anymore & the only thing we could do is add refrigerant but it would eventually leak. She said she’d keep an eye on it to see if it struggles in the near future & go from there, no other issues to report.


joshua.megacare@gmail.com

joshua.megacare@gmail.com Job Checkin

Customer didn’t know there was another filter to change, took out filter and pressures got better but of course coil is dirty and still affecting pressures recommended cleaning customer said he would take care of it.


Erik R.

Erik R. Job Checkin

Home owners friend that was house sitting was was trying to control the temperature off the alarm system, & thermostat on alarm system was malfunctioning. Mentioned the thermostat was around the corner & turned the temperature down on the actual thermostat & the unit began cooling instantly. No issues to report.


Erik R.

Erik R. Job Checkin

Contactor was burnt up & condenser fan motor had a bad capacitor. Swapped out both & the unit began cooling properly again. No other issues to report.


joshua.megacare@gmail.com

joshua.megacare@gmail.com Job Checkin

Unit just needed drain cleared. Other than that good to go


Erik R.

Erik R. Job Checkin

Completed cooling tune up, everything checked out good to go. No issues to report.


Erik R.

Erik R. Job Checkin

Dual capacitor was bad, changed it out then checked pressures. Pressures were low & evaporator coil was frozen. Thawed it out then found the leak with my camera. Mentioned I could charge it up to get him by until I get him the estimate for the coil replacement. Went ahead & added 4lbs of 410A & signed up 2 systems on memberships. No other issues to report.


joshua.megacare@gmail.com

joshua.megacare@gmail.com Job Checkin

Upon arrival unit was running with thermostat on. Did a full diagnostic of the system and didn’t see any signs of disturbance. Tightened connections and called it good


Erik R.

Erik R. Job Checkin

Completed cooling tune up, condenser was pretty caked up with dirt, other than that everything else looked good to go, no other issues to report.


joshua.megacare@gmail.com

joshua.megacare@gmail.com Job Checkin

Board was giving code for a faulty float switch but drain pan was clear. Replaced switch and added pan treat to help drain water. Air conditioner was repaired and unit was running.


joshua.megacare@gmail.com

joshua.megacare@gmail.com Job Checkin

Wasn’t getting 24v to outdoor unit and also to thermostat. Looked at indoor unit and had water in drain pan which activated the float switch. Cleared drain and got unit cooling. Customer wanted to reschedule for tune up


Erik R.

Erik R. Job Checkin

Inspected unit has burnt blower motor, blower housing, blower motor, blower wheel and heat strips need to be replaced. Company did not agree with the price and will find an alternative somewhere else. customer that lives in home doesn’t have the money for replacement he will find parts on his own


Manny G.

Manny G. Job Checkin

Duct cleaning to remove dust, dirt, debris, and other contaminants from the ductwork. Application of a disinfectant to eliminate mold, bacteria, viruses, and other harmful microorganisms that may be present within the ducts. Cleaning of air vents and registers to prevent the recontamination of the ducts and float switch on coil for 4 ton unit.


Manny G.

Manny G. Job Checkin

Completed estimate for duct cleaning and float switch on coil for 4 ton unit customer will call office to schedule