As I arrived, the homeowner greeted me at his garage Homeowner States that it has been running fine This is Lennox Split system, air handler, vertical in the garage condenser locate on the left side ground level Changed out the filter and noticed some water on it. Ask the homeowner if he’s using more than one filter and he’s been double filtering Tested all voltage and components and connections at the air handler and at the condenser Turbo capacitor is under spec on the fan side. This would be under warranty for replacement. Evaporator van blower motor capacitor under spec not in warranty Sprayed off the entire condenser coil and found quite a bit of dirt and dust inside. This also could be causing the fan side on the capacitor to be wearing down prematurely due to inadequate airflow through the coil. The pure air c two bulb 12 inch is down and after confirming with Chase, he is sending us a new one. I do not have this on my truck. I have every other pair but this one I cal