Both technician was hard working professional. Kind and patiently explain and helping me to understand and know about my new AC system I was very happy and satisfied with their service.
This is our 2nd time using Total Air (we’ll use them again.) Prompt service and show up when they say they will. Kind folks from call taker to techs. Knowledgeable and fair prices.
This company has never let me down. Every technician that has come out for tune ups has been wonderful!! Excellent service again today with Caleb!
Really happy with how our technician was able to find the issue causing our home not to cool and then promptly fixing the issue the same day. I now feel confident heading into a Florida summer!
Your technician Michael was very professional and represented your company well, solved the problem quickly and resolved the issue. He is a great asset to the business. Highly recommend them for your HVAC needs. Ever the office staff teats everyone with respect and was a pleasure talking to them about other services they offer with I gladly accepted to insure everything runs well. The response time was awesome.
My AC technician Mr. Cuberi was both professional and personable. He explained the situation in layman's terms so I could understand the problem.
Very good service, explain what was wrong with air..very professional..
Excellent Service! Michael was so polite, very efficient, and explained everything! Will definitely use Total Air again!
T6 Thermostat Completed full maintenance on a split system unit Checked all wiring and components Tested refrigerant levels and temperature Tested Capacitor Tested fan and compressor amps Took temperature splits from supply and return Tested blower wheel amps Tested float switch Vacuumed and flushed condensate line Unit is up and operating at this time. I installed a thermostat. Unit didn’t seem to be starting up and shutting off properly. After installation and programming the unit is starting up and shutting off properly and good to go.
Consultation Code: ENG9KQRGT upon arrival, meet and greet customer go over Work scheduled for the day start tearing out, rooftop condenser and inside furnace cut hole inside of new furnace for return air for return. Air seal Plenum on new unit or 11 flush copper line set hook up, copper at new furnace and new condenser on rooftop nitrogen test 400 psi for one hour pump down to 500 µm. New thermostat new flow switch new drain to wall. Will need to return with running P-trap and correct breaker for unit. Everything else is complete and job is finished. Customer asked to leave gas off at furnace You need a double sided breaker one side of 15 one side a 20 each side is a single pole
Upon arrival, homeowner greeted me at the door. I checked out the whole entire system. All voltage connections and um draws the air handler is spotless. I do recommend a UV light but the pure air electrostatic filter is doing a great job keeping the unit clean. I went outside to the condenser and checked all voltage components and Atras turbo capacitor is working great. The refrigerant charge is not OEM specs Needs a slight adjustment after homeowner approval. I’ve got the required refrigerant needed to get OEM specifications. I can already feel different inside the home . Protection outside is working great a hard kit could lower the Draws of the condenser unit, possibly lowering the electric bill every single time it turns on Recommend UV light on inside Evaporator coil also a hard star can could help on the condenser outside for a lowering amp draw on every single turn on, possibly lowering the electric bill and ensuring a longer lasting condenser.
Warranty Evaporator Coil Furnish and Install Warranty Evaporator Coil Furnish and Install Liquid Line Filter Drier Recover Refrigerant Cut/Braze Copper Lines Add/Adjust Refrigerant Perform Start Up Procedures 6-23-25 NM Arrived onsite to help Caleb install the new evap coil. Had to put new screws into the attic access to hold the panel. Brazed with nitrogen, filter drier was in outdoor unit so did not need to be replaced. Mounted sensing bulb properly and insulated. Pressure tested at 250 for 15 minutes. Checked with Stuart to make sure we were good with pressures. Temp split 20 degrees at this time. Microns down to 180 microns. Confirmed with Stuart that unit was working properly.
is there arrived was greeted by The homeowner went straight to the roof and started pumping down the system so I could do the TXV replacement Re-insulation of the unit. Vacuum down the system to 5 µm and tested the system and held sucked out the drain line and cleaned up the inside of the unit turned everything back on UV light still works great system back up and running to look at unit that was down. We just did it on this call, the evaporator coil leak the compressor is burnt. I need to change the plug compressor and the evaporator coil homeowners would like me to install a low pressure switch to make sure this does not happen again as there is no pressure switches on the system. Job will be done another day
Found system with a bad compressor after installing hard start capacitor and contactor. Customer will reach out to home warranty company about a system replacement. If this does not work out then he will reach out to Chris our Comfort Advisor. Was able to complete full maintenance.
Check all electric components.ohms compressor and condenser fan motor.check capacitor.check pressure.clean drain line.replace filter.check air handler.Evap coil.blower motor and the blade.recommend UV LIGHT.clean evaporator coil in its place..
Perform maintenance on split system checked refrigerant charge, and temperature split. Checked over electronic components took an readings and tested capacitor. Installed flow and UV light to keep system clean and maintain drain line. Unit running and cooling at this time.
The heater was disconnected, we adjusted some cables, primary drain pan is cracked We will return to change the primary drain and clean the coil. System running and operating at this time
Checked all major components: Freon levels compressor , fan motor , capacitor, rinsed condenser coil, flushed drain line , checked filters . Based on readings capacitor is reading lower than it’s rated and contractor points are burned and are making compressor to work hard . Unit is 14 years old . Recommend customer to see options for a new unit. Customer wanted to replace capacitor and contractor for now.
The system is completely frozen. We leave the fan on to defrost. He says this unit is under warranty with another company
Condensate drain was clogged Vacuumed and flushed with drain solve Iflo was installed System running and operating at this time
SEND A ADVISOR TOMORROW HERE No Freon oN this system +20 years old
A new thermostat cable was run as it was too short, the drain was clogged Vacuumed and flushed condensate drain with drain solve Iflo was installed The client opened a hole in the wall to run the cable System running and operating at this time
6-21-25 NM Arrived onsite and homeowner informed me what was going on. Found that the condenser fan motor was weak on start up. Found that the fan motor finally failed as I was informing customer of the situation. I offered a CA to come out with a portable unit. They want to try to go after the company that put it in. They would like us to follow up Monday. Would recommend the unit be replaced at this time by professional install crew, with all new warranties. Customer declined ca while I was here.