We have an 80 year old home that had 50 year old duct work in the attic. The replacement took 4 days to remove and install a complicated system in high temperatures. Josh and his team stayed on it and did not leave until everything was right. The pricing/cost was higher that n competitors but worth it. I recommend Total Air.
Total Air is always the best in customer service and support for keeping a trouble free AC system running smoothly for my home
Top notch Tech! Came recommended from my next door neighbor. Fast customer service.
Wade did an excellent and thorough job. Highly recommend him!
Stop looking around for who has the best AC service and customer support A friend recommended Total Air to me over 3 years ago and trust me they are 5 stars across the board
Marvin is an exceptional technician. He is extremely knowledgeable and professional.
Technician Tom was knowledgeable about his field and knew how to address and fix the issue.
Warranty Motor and Control Board. Replaced condenser fan motor and defrost board. Unit now running and cooling at this time. Pressures look normal.
Upon arrival found outdoor unit not running and shut off high-pressure. Was able to get the fan to come on for enough time to complete a full maintenance on the system, but fan would no longer run after that outdoor fan needs to be replaced as well as the outdoor board, which is discolored.
Arrived on site to find condenser not running. Fan wire was disconnected from capacitor. Reconnected wire to find capacitor was reading low and compressor and fan had overheated. Replaced capacitor and cooled off fan and compressor. System came on and is running an operating at this time.
Checked all major come on the ac unit: compressor fan motors , capacitor, Freon levels, temp differentials, flushed drain line, checked filters. Based on readings Capacitor was lower than it is rated which means that is going bad and need to be replaced . Also compressor has started to work hard and need to add a hard start kit on to make it work smoother. Blower wheel is dirty and need to be cleaned. Customer want to schedule the capacitor for another day.
Checked all major come on the ac unit: compressor fan motors , capacitor, Freon levels, temp differentials, flushed drain line, checked filters. Based on readings unit Is working good for now. The armored on the suction line outside was ripped off and replaced 7 feet of it. Also recommend to customer to add a hard start kit to make compressor work smoother
4 new returns, 9 new supplies. Permits and inspections included. New 5 inch media filter. 5 year parts and labor guarantee on ductwork. all new ductwork installed after tear out of all metal ductwork, new Plenum new heat shield, new media filter on return Air side 34 new cutting for return Air pictures taken of all work completed supply trunk lines ran to mixing boxes mixing boxes to the diffusers everythingt to has dampers at mixing boxes for supplies complete
Replaced condenser fan motor out of warranty and also unit was undercharged and added 3 lb of freon . Unit is working good now. Customer may be interested in membership
Customer complaining no cool. After evaluating the entire system noticed that outside fan motor was bad and wasn’t coming on . Need to check for warranty and give the quote . Motor need to be replaced
Upon arrival customer said that unit is not turning on. Outside unit was working but the blower inside is not coming on . The blower is bad . And blower wheel is dirty and need to be clean . Customer accepted to go ahead and do the service . Need to schedule another day for replacing the blower motor when we have it. Day 2: replaced blower motor , cleaned blower wheel, flushed drain line, checked the Freon and it was low the shrewder valve was leaking, replaced shrewder valve and add 1 pound of Freon. Customer is aware of maintenance membership.
Customer said unit is not cooling . Checked the Freon level were nearly 0 added e little bit of Freon and pressure test it with nitrogen and checked with sniffer and it was leaking from the evap coil . Customer need a quote for replacing the evap coil
Ruud 2 Stage Heat Pump Full system horizontal install includes: Remove and dispose of existing equipment and materials,Install new air handler in existing location, Install new outdoor unit and pad at existing location to code, New hang kit, drain pan, float switch. Safety overflow switch for drain line. Verify proper condensate drainage with Drain Solve. Mastic seal immediate duct connections. Recover refrigerant per EPA standards. Flush line-set. Charge system to ensure maximum efficiency. Adjust fan speed if necessary to accommodate static pressure of ductwork. Electrical safety: We will ensure your system is installed safely and according to code. Any unforseen electrical not included in initial proposal will be at the expense of the homeowner. Complete clean-up including drop cloths and shoe covers. Permits and Inspections of AHRI certified equipment to code. All work to be performed in a neat and professional manner in accordance with existing codes by trained technicians. 1
Media Replacements Filter 20x20
Uv light is in good working condition. Found dirty filter, highly recommended replacing. Customer ordered new filters from filterbuy. Found buildup by one of the supply grills, the grill wasn’t flush with the ceiling. Tightened grill to ceiling. System is working properly. - Collin
Upon arrival, found system off, not working. During inspection found blown five and fuse.Tstat was wired wrong with common in the wrong terminal. Also float switched failed not allowing 24v to kick the system on. Recommend replacing float switch and 5 amp fuse .
Customer did not want a maintenance done today when she called into the office she said that she needed to have the upstairs air handler in the closet cleaned of mold, which would include cleaning the blower and blower assembly. Also doing a very deep clean on the evaporator coil. The last time that Dakota was out here he let this customer know that they could call Dell air and have their blower motor replaced because it was under warranty. When Del air came out and replaced the blower motor, they also did the entire maintenance on all the systems. That was right before Christmas. Also she said that Dakota was here in September and did the maintenance and he was the one who suggested that they Get the upstairs air handler cleaned I let this customer know I said I apologize for the confusion. I gave her pricing for the Pull and clean on the blower and blower assembly and I also gave her the price for cleaning the evaporator coil. I let her know if she renewed that 20% would be taken of