Checked all major components: Freon levels compressor , fan motor , capacitor, temperature split, static pressure, flushed drain line , rinsed condenser coil, removed leaves from condenser,checked filters. Based on readings compressor has high start up amps and Evap coil is very dirty and need to be cleaned . Recommend customer to add a hard start kit to lower those amperages and do a pull and clean coil . Also recommend customer to get an electronic air cleaner to prevent this happening in the future . Customer agreed to do the hard start kit for now. on arrival, meet and greet with customer get started with work scheduled for the day pump system down, unhook from drain line low-voltage for flow switch and copper all unhooked to pull coil and clean clean coil outside pictures taken of all work completed clean inside and outside of entire cabinet checked all components outside for amperage’s and N everything checks out to factory specs job is comple payment is collected