Thomas and his crew worked so hard in the cold, for 2 days! They were very professional and had very good manners.
Overall Experience
Quality
Price
Convenience
Very professional, helpful, and trustworthy. I’d definitely like him as my technician when I call again.
Overall Experience
Quality
Price
Convenience
Tim was great. He came and got the job done quick and efficiently, arrived on time and was very honest about what work was necessary, and just seemed like a great guy.
Overall Experience
Quality
Price
Convenience
Jonathan and Zach went above and beyond with our projects.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Tim and Zack from Dawson’s Electric were very knowledgeable on setting up outdoor floodlight and security cameras as well as whole home surge protectors. They were able walk me through step by step and showed how they laid and routed hard wires in my attic. Would highly recommend this team and Dawson’s Electric
Overall Experience
Quality
Price
Convenience
Dawson’s Electric was great! Very professional, easily identifiable, polite, friendly and thorough.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Tim and crew did a great job in a timely and thorough manner.
Overall Experience
Quality
Price
Convenience
The service person was outstanding. Knew his trade, and made a couple of suggestions which I appreciated. Would definitely recommend this company, and would use them again.
Overall Experience
Quality
Price
Convenience
Jim, Mason and Zac were awesome! Good service, very professional, good quality. Recommended!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Thank you for honoring military with a discount. Jim and Curtis were thorough and polite. A credit to heir employer
Overall Experience
Quality
Price
Convenience
Completed PTAC unit installation with customer-provided equipment. Inspected electrical sub-panel to ensure proper circuit configuration and verified heat exchanger/condenser coil integrity (unit serial #2406G15902, model #PZH09K3SC) prior to final installation and testing.
Performed scheduled preventative maintenance on a 2022 Lennox ML14XC1-042 HVAC system, including complete 80-point inspection. Cleaned outdoor coils and burner assembly, adjusted gas pressures as needed, and verified proper amperage draw of 1.18A during operation. All safety inspections were completed with no issues identified.
Completed installation of outdoor GFCI outlet for customer's gazebo by adding a dedicated circuit with trenching. Inspected main panel to determine available capacity, installed GFCI breaker, and ran appropriate wiring through trench to gazebo location to power customer's smoker and accessories.
Responded to service call for front porch light replacement and flood light bulb installation. Upon inspection, discovered significant corrosion on electrical components in the main panel, particularly around Siemens device mounting points. Replaced chandelier fixture on front porch, replaced flood light bulb, and documented electrical panel condition with labeled circuit breakers for future reference.
Inspected 10-year-old PTAC unit (unit #89+1) that was not producing heat. Discovered significant deterioration and corrosion on internal components, including visible holes and damage to the chassis panel. Performed electrical inspection of the circuit breaker panel to verify power supply, finding no electrical issues at the source.
Performed comprehensive 32-point electrical system evaluation including torque verification and connection inspection of main electrical panel. Tested all GFCI outlets and Arc Fault breakers for proper functionality, confirming the FirstSurge protection system is operating correctly with green indicator illuminated. Completed smoke and CO2 detector maintenance with battery replacement and functional testing.
Performed comprehensive 80-point HVAC preventative maintenance on 12-year-old unit, including cleaning of severely dust-impacted outdoor coils, burner cleaning, and gas pressure adjustments. Electrical connections were inspected, revealing bundled wiring at terminal connections that required attention during the safety inspection portion of the maintenance service.
Conducted 32-point electrical system evaluation on 2013 home, including electrical panel maintenance with proper torquing of connections. Performed safety testing of GFCI/Shock protection outlets/breakers and Arc Fault/Fire protection breakers, confirming all components functioning correctly.
Responded to service call regarding home inspection findings. Replaced expired smoke detector as required by home sale inspection. Evaluated electrical setup for washer/dryer installation and installed appropriate breaker to protect water source appliances per code requirements. Documented existing electrical service panel and meter configuration with photos for record.
Performed comprehensive 32-point electrical system evaluation including panel maintenance with connection torque verification. Tested all GFCI outlets, Arc Fault breakers, and smoke/CO2 detectors for proper functionality, replacing batteries as needed. Inspected exterior meter installation which appears well-maintained with no visible issues.
Conducted comprehensive heating and air maintenance including 80-point inspection on all units with cleaning of outdoor coils, burner cleaning, and adjustment of gas pressures as needed. Verified proper duct insulation in attic space and addressed customer inquiry regarding AUX heat indicator on thermostat, explaining normal operation of auxiliary heat function during heating cycle.
Completed electrical troubleshooting in kitchen where two switch plates were non-functional. Inspected main electrical panel to diagnose issue, found disorganized wiring causing intermittent connection problems. Resolved switch plate functionality by rewiring connections and securing loose wires in panel.
Completed site assessment for EV charger installation at new construction residence. Inspected main electrical service panel (200A) and documented existing circuit configuration. Panel has adequate space for new 50A 240V circuit required for Level 2 charger, but customer is reviewing competitive quotes before proceeding with installation.
Successfully installed and configured a SimpliSafe security system for the customer, including mounting a video doorbell with operational LED indicator and an outdoor camera. All components were properly wired, tested for functionality, and verified to be communicating with the customer's system.
Conducted site evaluation for upcoming hot tub installation. Inspected main electrical panel to assess available capacity for new 240V circuit. Documented existing breaker configuration and wiring to prepare comprehensive quote for installation of dedicated outlet and final connections once hot tub is delivered.