Today I came to Blaine’s Hidden Valley home to perform a furnace tune up before winter. Earlier this year Clearview replaced the inducing motor. In 2021 Clearview replaced the control board and igniter. Furnace tune up: Upon tune up and inspection of the 13 year old system I tested and adjusted the gas valve, burners, gas pressure and temperature rise. Pulled and cleaned the flame sensor. Tested ignition system, inducing motor and assembly, blower motor and assembly, heat exchanger, humidifier, static pressures, tested and tightened all electrical connections, all safety switches and control board. The furnace is in good condition. All components are working well within manufacturers specifications. The humidifier was allowing far too much water to flow through it. I throttled the flow down at the needle valve which will save lots of water. The water heater is 16 years old and well past its life expectancy. The Bradford white gx2 is a performance tank. It is only 25 gallons but is a