Today I came to Chris’s Roxboro home to perform the annual family plan boiler system inspection and service on the 13 year old system. Boiler service: Upon inspection and maintenance of the 13 year old system I tested and adjusted the boiler, heat exchanger, ignition and flame rectification systems, venting and gas lines. Checked all pumps and zone valves, piping and controls. Check air elimination devices and expansion system. Tested glycol levels, hydronic feeder, and general system operation. The system is in poor condition. The main system pump, domestic hot water pump, and slab pump are all over amperage indicating impending failure. There are 3 leaking and failed auto air vents. The boiler heat exchanger needs to be cleaned as it is very dirty. Tech returned November 7 to replace air handler circulation pump as well as replaced three air separators as well as disassemble boiler heat, exchanger and cleaned tech shut off boiler and replaced auto air vents and then replaced the