Job Checkin

Today I came to Amber and Russ’s Bridgeland-Riverside home because the water heater stopped working. Upon diagnostic of the 11 year old system I found it to be in poor condition. The 75 gallon direct vented tank serves 1 zone of under slab heating in the basement. This connection is not to code and deemed hazardous to your health. The water pressure in the home is over 100 psi which is the main cause of the problem here today. Because the water pressure is so high, the tanks temperature and pressure safety relief valve is leaking. This leaked onto the flammable vapour sensor and caused it to fail.the hydronic panel also has 2 active leaks. There is no water softener in the home which negatively effects everything using water in the home. Scheduled to return Monday march 27 2023 for boiler install. $5000 collected today with another $5000 to be collected Monday and the remainder due at time of job completion. 25% restocking fee should the job be cancelled.