Was only able to complete the air handler portion of the maintenance as it is raining and thundering. Checked temperature differential insured UV light was working. Checked amp draws on blower. Tested float switch. Checked condition of coil and blower assembly. Recommend a pull and clean on the blower motor and the adding of an electronic air cleaner to prevent future buildup. We need to return to complete outside portion of the maintenance. 7-2-25 NM Arrived onsite and performed semi annual maintenance. Inspected outdoor unit and rinsed down outdoor coil and gave unit a bubble bath. Removed all leaves and debris from the outdoor unit. Noted the gutters should be extended to protect the unit or future unit from rust and corrosion. Did find a weak capacitor outside. I installed a new one at this time. Checked customers warranty and found it expired 3 days ago. Outdoor unit is sounding pretty rough with the compressor but it’s working I did bring this up to the homeowners attention