Install Mitsubishi Dual Zone Mini Split. Run new high volt and low volt wires. Run new copper line sets with covers. Install floor mount 12k btu in living space area. Install floor mount 9k btu in bedroom. Run new drain lines. Install Hurricane pad with condenser leg stand to raise to floor level. System comes with Twelve Years of parts and one year of labor warranty. Permit and inspection by the county Install new 18 BTU mini split floor head mount and nine BTU floor head mount run new copper underneath house drain line out wall and down on side of house for both heads nitrogen test line set 400 psi for 45 minutes vacuum down to 500 µm start up checking cool and heat modes System is running and charged to factory specs job is complete pictures taken of all work completed. Check collected.