Responded to service call for non-functioning downstairs gas heating system. Diagnostic testing revealed low voltage reading of 18.5V at control board (below required 24V threshold). Further investigation showed 54°F temperature in attic space affecting system operation. Restored proper voltage by adjusting transformer connections and verified blower motor operation. System now functioning normally with proper heat output.