Today I came out to your home to perform your yearly Peace of Mind Electrical Checkup. During the visit, I inspected the home’s wiring, safety systems and devices, electrical panels, and grounding system. A full walkthrough of the electrical system was completed to verify that all accessible components were operating safely and as intended. Unfortunately, several significant safety concerns were uncovered regarding the overall condition of your electrical system. The original portion of the home is wired with ungrounded wiring, which does not provide a safe path for fault current. In multiple areas, devices have been upgraded to three-prong receptacles without the addition of proper GFCI protection (Shock Guard Protection), creating a false sense of grounding and increasing the risk of electrical shock. The electrical panel was also found to be obsolete and presented several safety issues, including being installed inside a clothes closet, missing Romex connectors, and lacking AFCI br