6220 Lower York Rd
New Hope, PA 18938
(267)406-6050

Job Locations
for upper black eddy, pa


Map of Upper Black Eddy PA
Chris G.

Chris G.


Job Checkin

Jet Pump to submersible pump conversion. - Excavate at the well head to install a 1" stainless steel pitless adapter. - Install a 1/2 HP 10 GPM 230V 2 wire SS submersible pump with new 160PSI black pipe and 12/2 flat wire/cable with a ground. - Install a new 12/2 wire in the lateral line conduit currently used with the 2 pipe jet pump - Remove and dispose of old jet pump. - Install new fittings as required to tie into the existing well tank