The old system was in upflow, I replumbed it to down flow. Hardness-0 Ph-7.3 Iron-0 TDS-276
Measured the well and it’s 35’. The well does not have enough water.
Locate, excavate and raise the wellhead with welded 6" steel. Install a new pitless adapter and well cap. Excavate and install a new water and electrical lateral line. Install a Shallow Well 1/2 HP jet pump and a 20 gallon well tank with associated fittings Seal foundation wall with hydraulic cement Sire work: We work to limit the area of disturbance and we are not responsible for site restoration or private utilities (low voltage lighting, sprinkler systems and the like)
Review pictures to see if job is doable. Finished basement
Water test and customer is looking into a carbon unit in Center carbon
Look at customers jet pump, pretty much unfixable we presented the dab booster pump and he is interested to go through insurance, so John might have to talk to the insurance people
Replace existing well tank with a new WR120 (WellRire) 33 gallon unit. Install a new tank T assembly with pressure relief valve, boiler drain, check valve, pressure gauge and stainless steel T pipe assembly. Remove and dispose of the old unit.
Install new well tank Lawrence Township