30045 FM 2978 Rd.
Magnolia, TX 77354
2816515484

Our Top Cities


Local Reviews
for spring, tx

Rated 4.9 out of 5 stars based on 949 customer reviews

Thank you!

It is a pleasure to work with such competent people!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Happy with the service

Jeremy came to fix one of our a/c units. He was thorough, competent and very polite. We love Bradbury Brothers.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Solved my problem

I was so grateful to get new service on a weekend! Juan was so pleasant to work with. His honesty on his findings and how he taught me what needed to be fixed in priority. He got down to earth with me about the current national crisis and our jobs. So I’m blessed to have someone like Juan come fix my ac. Thank you so much!!!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great Service

  • Overall Experience
  • Quality
  • Value
  • Professionalism

AC quote for my home.

Very knowledgeable guy and polite.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

A/C assessment

Jorden was very professional, thorough, and courteous in his assessment of our A/C system.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Great service

Explained everything, very friendly

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Very Professional

Very professional. Good quality inspection and reasonable recommendations.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Outstanding service.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Job Locations
for spring, tx

Jeremy D.

Jeremy D. Job Checkin

Diagnostic System: Downstairs Notes: On arrival blower motor was operational. Condenser was not operational. Found faulty thermostat wiring at connector junction. Wiring is weathered and no more can be drawn from house. New thermostat wiring will need to be ran. Will require two techs and saws-all.


Juan  M.

Juan M. Job Checkin

Diagnostic System: Refrigerant Type R22/R410A Metering Device-Fixed Orifice/TXV SP/HP SLT/LLT VSAT/LSAT SH/SC Outdoor Entering Air Temperature Notes: upon arrival customer stated that air was blowing but not air. Went into attic to see if blower was operational. Then went to see condenser found that cap was rated 45/5 and it was at 0/2.1 went and told customer what happened and she agreed on changing cap and adding hard start kit to regulate compressor. While checking system out found multiple issues also outside line isn’t insulated, unit does not have any overflow protection and supply plenum is covered in organic growth presented issues to customer but she would like just to get the unit running for now and have this stuff brought up again on tune up. System is operating at this time. Recommendations:


Juan  M.

Juan M. Job Checkin

Diagnostic System: Refrigerant Type R22/R410A Metering Device-Fixed Orifice/TXV SP/HP SLT/LLT VSAT/LSAT SH/SC Outdoor Entering Air Temperature Notes: customer stated that system would not cool but would blow air so went to check condenser and found fan not working but compressor was. Popped open door and was getting 24 volts from the contactor but fan motor was not operating. Fan motor is a multi speed motor that is not powered by capacitor it’s connected directly to contactor. Told customer that office will check for availability and warranty and will be in contact with her on Monday to see what she would like to get done. If we could get a senior tech to see how we could fix her ductwork she would like that as well. Recommendations:


Jorden S.

Jorden S. Job Checkin

Has gotten 6 other quotes, they were all 2000 less


Fernando G.

Fernando G. Job Checkin

System- D/s system Approx Age of System: 10 Refrigerant Type- R410a Metering Device- TXV SP/HP: 117.1/254.1 SLT/LLT: 54.3/83.4 VSAT/LSAT- 39.4/84.4 Superheat/Subcool- 15.3/1.1 Outdoor Entering Air Temp- 76.1 Outdoor Fan FLA- .9 Compressor RLA/LRA- 7.8/92.3 Contactor Voltage- 241.5 Capacitor Rating- 41/7.5 Indoor Return Dry Bulb Temp- 66.8 Return wet bulb- 42.3 Supply Temp- 49.6 Temperature Difference- 17.2 Required Difference- 16-20 Blower FLA- 8.19 Filter Sizes – 20x25x1 Changed Filters – Y Blew out drain line: Y Notes- system reads low on refrigerant at this time condenser coils have heavy dust build up that may not allow proper heat exchange. A thorough chemical cleaning would allow the system to remove heat easily with out causing strain on the equipment, or affecting refrigerant readings. The system is starting up with high initial energy draws at this time the compressor saver is in need of replacement to reduce these high starts and strain on the compressor. Next Sc


Jeremy D.

Jeremy D. Job Checkin

Returned and installed blower motor and control board. Checked for proper operations. All authorizations, payments and permissions were given via phone by Mr. Travis.


Ken P.

Ken P. Job Checkin

Diagnostic System: Main Refrigerant Type R410A Metering Device TXV See attached photos Outdoor Entering Air Temperature 85° Notes: Upon arrival system was low on refrigerant. I opened the coil and and applied leak bubbles to coil finding leak in lower right corner. System warranty expires in august, advised Mr Milam to consider replacement since this is a major repair at the end of the systems warranty life, if the compressor or condenser coil next year it will no longer have a warranty and require replacement. Head pressure was high even though system was overall low on refrigerant due to dirty condenser coil. Advised if going through with warranty coil to have condenser cleaned and start kit installed to get as much life possible out of the outdoor unit after warranty expiration. Mr Milam wants to go through with warranty coil, I performed condenser cleaning and installed a start kit today. Also added 2 pounds of refrigerant to keep system cooling over the weekend. If still under 5


Mario S.

Mario S. Job Checkin

System analysis x1 Condenser unit had blown compressor saver and coils were extremely caked. Recommended and installed a new compressor saver and performed major coil cleaning on condenser. Tested the unit and checked refrigerant and system is fully operational. No other issues are visible at this time. System analysis part 2 After finishing call I was leaving and received a call from Anthony stating it was cooling and then suddenly stopped. Came back and inspected the condenser to find the control board smelling burnt and no longer functional , control board was receiving power but not coming on. Also inspected the capacitor and now capacitor is no longer reading any mfs. Was able to replace capacitor today but will need to return to replace control board tomorrow morning. Customer would like us to contact him when we receive the board and before going to the home. Model is hard to read but in person it does seem to say RAPM-060JEZ


Shane B.

Shane B. Job Checkin

Free annual home inspection. Items of concern master shower handle loose tried to tighten but handle will not come off without breaking cartridge and trim, estimates will be provided. Adjusted downstairs hall toilet flapper. Customer is still awaiting parts for kitchen faucet


Hayden H.

Hayden H. Job Checkin

System- 1 system 2 zones Approx Age of System: 4 years old Refrigerant Type- R410a Metering Device- TXV SP/HP:130/353 SLT/LLT:67/101 VSAT/LSAT-44/108 Superheat/Subcool- 21/6.5 Outdoor Entering Air Temp-86 Outdoor Fan FLA- 0.73 Compressor RLA/LRA-16.73/57 Contactor Voltage-243 Capacitor Rating-35.2/4.7. 40/5 Indoor Return Dry Bulb Temp-74 Return Wet Bulb Temp-64 Supply Temp-54 Temperature Difference-20 Required Difference-20 Blower FLA- 3.6 Filter Sizes – 20x25x4 Changed Filters –yes customer had them to change out Blew out drain line: Yes Notes- Recommend UV light for better indoor air quality, also kills organic growth from forming and even kills bacteria. Scheduled next tune up date:


Marc H.

Marc H. Job Checkin

Homeowner called us out today due to broken half-inch line in the wall behind the upstairs guest bath toilet. Cut a hole about 8“ x 8“ and made repair to pipe also installed supply stop and supply tube. Let glue dry on the CPVC pipe for 30 min. Made homeowner aware we are not Responsible for patchwork


Jeremy D.

Jeremy D. Job Checkin

System- Upstairs/Left Side Approx Age of System: 7yrs Refrigerant Type- R410a Metering Device- TXV SP/HP: 91/305 SLT/LLT: 78/96 VSAT/LSAT- 26/96 Superheat/Subcool- 51/0 Outdoor Entering Air Temp-90 Outdoor Fan FLA- .9 Compressor RLA/LRA-6.3/56 Contactor Voltage- 245/26 Capacitor Rating- 33.99/4.98 Indoor Return Dry Bulb Temp- 77 Return Wet Bulb Temp- 55 Supply Temp- 66 Temperature Difference- 11 Required Difference- 16-20 Blower FLA-2.6 Filter Sizes – 16x25x4 Changed Filters – Clean Blew out drain line: N (no blowout valve) Notes- Unit was operational on arrival. Checked filters. Checked operating pressures and temperatures. Checked indoor and outdoor electrical. Blower motor capacitor is bad rated for 5mfd. Superheat is high and subcooling is low. Temperature split is low. Unit appears to be under charged. Condenser coil is clogged with debris. Through chemical should be done be any adjustments to charge are made. Unit has no overflow protection. All ot


Casey L.

Casey L. Job Checkin

Found the main living unit extremely low on refrigerant. This is an indication of a leak in the system. My standing R22 psi was at 23 psi. I recommend replacement of the equipment due to the age and the use of the old refrigerant. Mr. Bruno is going to get a quote but doesn’t know if he can financially do the replacement at this time. He asked me to go ahead and fill it up to restore cooling. I explained I wasn’t comfortable doing it due to seeing refrigerant leak out over night when it has been this low. He understood my concerns but wanted to proceed anyway. We added 7 lbs of R22 to the system to restore cooling at this time. We cannot guarantee the refrigerant going forward due to the potential leak. Unable to get static pressure as I didn’t have access to the attic space. Mr. Bruno will have stuff moved for the comfort advisor.


James W.

James W. Job Checkin

Cut out old pvc drain line for toilet in upstairs hall bath room . Had to cut out a little more Sheetrock to access all of the drain to make repair . Reconnected all drain and vent lines. Set toilet back and sealed bottom. Flushed multiple times to check for leaks and found none. Sheet rock was wet and falling down while performing work. Need to get restoration out to see how bad Sheetrock is damaged from the leak and how far is goes. There was patch work done in area I was removing Sheetrock .


Hayden H.

Hayden H. Job Checkin

System- upstairs Approx Age of System: 3 years old Refrigerant Type- R410a Metering Device- TXV SP/HP:125/327 SLT/LLT:63/95 VSAT/LSAT-43/101 Superheat/Subcool-19/5.8 Outdoor Entering Air Temp-86 Outdoor Fan FLA-0.64 Compressor RLA/LRA-7.12/56 Contactor Voltage-238 Capacitor Rating-40/5. (39.6/4.49) Indoor Return Dry Bulb Temp-75 Supply Temp-56 Temperature Difference-19 Required Difference-15-20 Blower FLA- 3.6 Filter Sizes –12x24x1 Changed Filters – No (clean) Blew out drain line: Yes Notes- Everything is cooling properly Next Scheduled Tune up Date: . . . . . . . . . System- downstairs Approx Age of System: 5 years old Refrigerant Type- R410a Metering Device- TXV SP/HP:136/354 SLT/LLT:58/101 VSAT/LSAT-45/106 Superheat/Subcool-11.6/5.6 Outdoor Entering Air Temp-88 Outdoor Fan FLA- 0.73 Compressor RLA/LRA-9.48/67 Contactor Voltage-237 Capacitor Rating-45.4/5.13 Indoor Return Dry Bulb Temp-73 Supply Temp- 56 Temperature Difference-17 Required Difference-15-20