Membership maintenance Checked all wiring. Garage system does not have a float switch. Vertical in bedroom has moisture sensor disconnected by homeowner. Took indoor blower motor amp draws. Blower wheels and evaporator coils are clean. No microbial growth found on unit interiors. Took air temperature split at supply and return. UV bulbs are working properly. Checked refrigerant pressures and temperatures. Tested capacitor microfarad. Compressor and outdoor fan motor amp draws. Washed condenser coil. The systems are running well at this time. Vertical system needs a UV bulb shield. The office has ordered this shield and we will return to install. Returned August 19 to install UV bulb shield. After install showed the difference to the homeowner who was happy with the result. Homeowner brought to my attention that recently the system had short cycled three times in a row. Tested system function while I was here, but did not find the system short cycling. Advised homeowner to give us a ca