Installation of 2.5 ton Amana 15.2 SEER2 Heat Pump and Air Handler, replace 3 ft of copper at condenser and AIr Handler, replace whip. All work to be performed in a neat and professional manner in accordance with existing codes by train technicians. Upon arrival, meet and greet with customer, go over Work for the day and get started tarp out from door to unit area that we will be working to protect get started tearing out old air handler and condenser replace coffin box new flush, copper line set and drain line, put new heat shield, and Plenum seal to unit at top mechanically fasten heat shield to Plenum and unit install new copper Inside and out about 4 to 5 feet inside same outside nitrogen test copper line set 400 psi for 30 minutes vacuum down to 500 µm start up check and cool and heat modes charge to factory specs. Everything is cooling to factory specs we have unit set all the way to the back of closet as well as coffin box. The drain line is coming out a little bit further than