We needed a correction to our PFAS issue after having our well water tested. John and his team came out next day, and installed our new tank to remedy the issue. Thank you so much. Would highly recommend them!!!
Excellent job done by knowledgable technicians.
Her PH was 8.3 . She has a Softner but it’s not working only bc she has no salt told her to buy more then we can put the system back on line. She also has a 4x 20 sediment filter.
Replaced U/V bulb and pre filter. Checked system settings and all regen cycles. Checked for leaks. All good. Hardness: 27 Ph: N/A Water tested soft, all good.
LOCATE AND EXCAVATE WELHEAD, RAISE WELLHEAD WITH WELDED 6" STEEL CASING, INSTALL A NEW PITLESS ADAPTER, SET A NEW 230v 3 WIRE 1/2HP STARITE SUBMERSIBLE PUMP (PUMP GPM TO BE DETERMINED AND WE ARE ASSUMING 10GPM FOR THIS PROPOSAL), INSTALL AN ESTIMATED 150' OF NEW 12/3 FLAT JACKET WELL WIRE, IINSTALL AN ESTIMATED 150' OF NEW 160 PSI BLACK POLY WELL PIPE, INSTALL A NEW WELL CAP, INSTALL A NEW 33 GALLON WELLRITE 120 WELL TANK. Well casing, wire and pipe are billed on a linear foot basis. Some additional fittings may be required and linear foot products and fittings will be itemized on our final invoice. Note: locating of the wellhead is often difficult and this proposal is based on an excavation depth of 4'. Site restoration is the responsibility of the homeowner and we work to limit the area of disturbance. We are not responsible for root and turf damage. The excavator is a rubber tracked device. Access to the wellhead is required and without overhead obstructions. We are not respon
Install a 1.5 cubic foot iron filtration system with a backwashing air injection Clack AIO filter valve. Install a 2 x 10 sediment filter and a GDS 8 Gallon per minute UV sterilization light.
Excavate and repair broken lateral line. Note: We will make a one call prior to excavating. We are not responsible for private utilities, irrigation systems, low voltage lighting, area drain pipes and the like. Every effort is made to minimize the area of disturbance and we use a rubber tracked excavator to perform the work. We will backfill the disturbed area and rake to the best of our ability. We ask that you turn off the pump the night before work is performed to help drain the soil. Broken lateral lines are routine. However, there are occasions when minor issues arise and adjustments to the work as proposed are required. We will keep you informed of the work progress and any issues that arise.
Looked over his equipment and provided installation restrains
Install a Clack Iron Breaker with an AOI filter valve, 1.5 cubic feet of Katalox media, by-pass valves, JG fittings and a drain line. All labor, equipment and fittings are included.
Install a one cubic foot PFAS reduction system w/ a 12 x 54 mineral tank and 110-SR resin
Replaced wire
Replace the existing water softener with a new Clack 48,000 grain metered unit.
Located wellhead and replaced 1/2 HP 7 GPM 230V well pump. Lateral line is compromised and needs to be replaced. Ran a temporary wire from the residence to the wellhead to establish power to the pump.
Clean ventur out and changed light . Softener may not be working