30045 FM 2978 Rd.
Magnolia, TX 77354
2816515484

Our Top Cities


Local Reviews
for cypress, tx

Rated 3.8 out of 5 stars based on 6 customer reviews

Poor communication everywhere

Bradbury Brothers installed a new system for me in 2015. During a 2018 tune-up, the technician noted the refrigerant was low and added some per the 2018 invoice. Wanting to address any refrigerant leak issue before my parts and labor warranty expires in 2020, I set up an appointment for today to see if there was a slow leak, and to get an external temperature sensor error fixed. There was very poor communication between the dispatcher and technician because the technician knew nothing of my primary concern about the leaking refrigerant and thought the only issue was the temp sensor. There was also poor communication between technicians with our account because the tech today incorrectly said there was nothing in prior invoices about the added refrigerant. While no leak was found in the evap or cond coils today, I'm still puzzled why refrigerant previously needed to be added. Because the refrigerant issue wasn't communicated and today was too cool for a pressure test per the technician, I will need to schedule another appointment to find out where a leak in the system may be. I'm extremely disappointed in these communication failures.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Marc did a good job


Response from Bradbury Brothers Cooling, Heating, Plumbing & Electrical:

Thank you for the 5 stars, Tom!

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Friendly Responsive Service

Technician came out quickly, assessed the issues and recommended various solutions. They were very friendly and even managed to get the air conditioning running temporarily while I decided on the next steps.

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Owner

The service is always good After the plumbing inspection however I was left with a question. Why didnt he flush a toilet? I have three! It seems like that would be part of the plumbing inspection?

  • Overall Experience
  • Quality
  • Value
  • Professionalism

you have good service

your a good company, good service. but you over charge! i had you work on my a/c. when you let, it started making noise. i called you back. you charge me again for a service call. you cg. 98$ to come out, then fix it, say 300$. i would think my service cg. would apply to fixing it. but i realize thats how you make your money, cg. every unit you touch is 98.00$. i have 4 units. you all love me!! and three homes. so i have about 8 units. you charge to much..

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Awesome Technician and service

  • Overall Experience
  • Quality
  • Value
  • Professionalism

Job Locations
for cypress, tx

Mario S.

Mario S. Job Checkin

Heater not heating. Heating repair and maintenance tune up. Diagnose and perform annual heater maintenance service plan on Ruud heating system. Replace filters and check furnace on 11 year old HVAC system. Heater maintenance complete which will help lower heating cost for this residential customer. R22 refrigerant was phased out in January 2020. Recommend replacement with new Comfortmaker air conditioning system. Heating system is now ready for winter weather.


Caleb J.

Caleb J. Job Checkin

Arrived to customers home for outdoor temperature sensor not reading correctly. Customer says that she has had this issue in the past. I have reset the thermostat and the temperature is now reading correctly at 53 degrees. I have checked the filters and found them to be very dirty. I have offered to replace the filters for the customer but they have declined at this time. They will be ordering filters online and replacing themselves. The customer brought to my attention that the UV light is not working. They would like to replace it today. I have replaced it with the Air Scrubber. Installed hooking in to its own transformer. I spoke with Mr. Stephen over the phone, he mentioned that he believes we had to put refrigerant in this system at stoke point or another. He asked if I could check refrigerant pressures. Unfortunately, with today’s temperatures, trying to check refrigerant pressures would be very inaccurate. The customer did approve me performing an electronic leak search o


Jim V.

Jim V. Job Checkin

We were out to look at a low water pressure situation. We were informed the issue was localized to one downstairs restroom. We tested everything and found that the aerators were clogged up. We removed them and cleaned them. Once we installed them back, we tested everything and they are working perfectly. Everything else looks good at this time. There is no follow up at this time.


Shane B.

Shane B. Job Checkin

Check dishwasher leaks when ran. Found water pouring out of air gap and leaking in cabinet and on counter top. Remove air gap and blow out hose with nitrogen to remove food particles, see pics of food particles. Put back together and tested. No more leaks at this time.


Ronald  E.

Ronald E. Job Checkin

Toilet is not flushing. Diagnose and find cracked toilet tank. Replace toilet tank and toilet is working properly at this time. Notice toilet is wobbly. Recommend pull and reset toilet to ensure stability.


Nic M.

Nic M. Job Checkin

Customer had us out today to do a whole home plumbing inspection. After completing the inspection we found the shower cartridge in the master bath to be getting hard to turn. Recommended replacement to prevent water waste or breakage. Also found rubber washing machine hoses. Recommended replacement due to the same thing as last time. Other than that home is still fairly new and had no other visual issues or drainage issues.


Michael C.

Michael C. Job Checkin

Toilet is making noises. Diagnose and find bad flapper. Replace flapper and toilet is working properly at this time. Notice scale build-up inside of toilet. Scale build up affects functionality of parts. Recommend Gemline water softener to reduce scale build up and preventing plumbing fixtures from hard water damage.


Michael C.

Michael C. Job Checkin

Heater not heating. Heating repair and maintenance tune up. Diagnose and perform annual heater maintenance service plan on Ruud heating system. Replace filters and check furnace on 16 year old HVAC system. Heater maintenance complete which will help lower heating cost for this residential customer. R22 refrigerant will be phased out in January 2020. Recommend replacement with new Comfortmaker air conditioning system. Heating system is now ready for cooler weather.


Michael C.

Michael C. Job Checkin

Heater making noises. Heating repair and maintenance tune up. Diagnose and perform annual heater maintenance service plan on Goodman heating system. Install compressor saver and check furnace on 10 year old HVAC system. Heater maintenance complete which will help lower heating cost for this residential customer. Evaporator coil is leaking. Recommend replacement evaporator coil, leak repair, or new Comfortmaker air conditioning system. Heating system is now ready for cooler weather.


Ken P.

Ken P. Job Checkin

Heater not heating. Heating repair and maintenance tune up. Diagnose and perform annual heater maintenance service plan on Daikin heating system. Repair wiring and check furnace on 14 year old HVAC system. Heater maintenance complete which will help lower heating cost for this residential customer. R22 refrigerant will be phased out in January 2020. Recommend replacement with new Comfortmaker air conditioning system. Heating system is now ready for Texas weather.


Casey L.

Casey L. Job Checkin

Hot water heater not heating. Diagnose and find leaking water heater. 9 year old American Standard water heater. Recommend replacement Rheem tank water heater, or Navien tankless water heater. Average water heater life span is 8-12 years old. Install new Rheem tank water heater with new pan and test for functionality. Recommend Gemline water softener to protect new water heater from hard water damage.


Juan  M.

Juan M. Job Checkin

System-right side Approx Age of System: Refrigerant Type- R410a Metering Device- TXV SP/HP: 127/278 SLT/LLT: 61/83 VSAT/LSAT- 44/90 Superheat/subcool- 15/7 Outdoor Entering Air Temp-84 Outdoor Fan FLA-.9 Compressor RLA/LRA-10.3/100 Contactor Voltage-245/26 Capacitor Rating-45/5 actual 45/5 Indoor Return Dry Bulb Temp-75 Supply Temp-55 Temperature Difference-20 Required Difference-15-20 Blower FLA-3.8 Filter Sizes – 24x24x1,12x12x1,12x24x1 Changed Filters – N customer just changed Blew out drain line: Y Notes- Next Scheduled Tune up Date: --------------------------------------- System- left side Approx Age of System: Refrigerant Type- R410a Metering Device- TXV SP/HP: 124/291 SLT/LLT: 5/81 VSAT/LSAT- 43/94 Superheat/Subcool- 13/12 Outdoor Entering Air Temp-83 Outdoor Fan FLA-.7 Compressor RLA/LRA- 6.5/60 Contactor Voltage-246/26 Capacitor Rating-40/5 actual 40/5 Indoor Return Dry Bulb Temp-73 Supply Temp- 56 Temperature Difference-17 Required Difference-15-20


Chris S.

Chris S. Job Checkin

Hot water heater leaking. Diagnose and find water heater is over 8 years old and should be replaced. 20 year old American water heater. Recommend replacement Rheem tank water heater, or Navien tankless water heater. Average water heater life span is 8-12 years old. Install new Navien tankless water heater with new pan and test for functionality. Recommend water leak protection device (FloodStop) to prevent future damage from water leaks.


Chris S.

Chris S. Job Checkin

Hot water heater leaking. Diagnose and find water heater is over 8 years old and should be replaced. 20 year old American water heater. Recommend replacement Rheem tank water heater, or Navien tankless water heater. Average water heater life span is 8-12 years old. Install new Navien tankless water heater with new pan and test for functionality. Recommend water leak protection device (FloodStop) to prevent future damage from water leaks.


Ticia R.

Ticia R. Job Checkin

20 year old Carrierair conditioning system not cooling. AC has old R22 freon and is past normal life expectancy. R22 freon will be illegal in January 2020. Install new Comfortmaker 5 Ton air conditioner, Furnace, and Evaporator coil with condensation package and R410A freon. Home is cool and ready for late summer weather.