Installation of Lennox XC16 16 SEER air conditioning system completed for residence in Piedmont. The new 3-ton variable-speed system replaces an aging 10 SEER unit that experienced compressor failure. Installation included complete replacement of indoor evaporator coil, refrigerant lines, and condensate drain system. Modified existing ductwork at air handler connection to reduce static pressure and improve overall system efficiency. Performed manual J load calculation prior to installation to verify proper sizing. System includes Lennox iComfort S30 smart thermostat for enhanced temperature control and system monitoring. Vacuum tested system to 350 microns to ensure complete removal of moisture and non-condensables. Charged system according to manufacturer superheat/subcooling specifications. Final testing indicates all parameters within optimal ranges with 19.2°F temperature differential. System is operating at 16.2 SEER under current conditions, exceeding rated efficiency. Provided c
During today's furnace maintenance visit, I focused on critical safety and efficiency checks. The furnace tune-up began with testing the heat exchanger for dangerous cracks using specialized detection equipment, followed by a thorough cleaning of the burner assembly to remove carbon buildup. I measured gas pressure readings at both inlet and manifold points, making necessary adjustments to optimize fuel consumption. The furnace maintenance also involved testing flame sensor sensitivity, cleaning the blower wheel, and checking all limit switches. I discovered the inducer motor showing signs of bearing wear, so I documented this for future reference and advised scheduling a replacement before next heating season.
Repairing a 5 ton Heil split system at performance package off of Augusta Road