Arrived for a no cool call. On arrival customers showed me to air handler unit. Saw condensate backflowing. Went down to condenser and found suction line extremely hot. Compressor was also hot. Melted insulation bag around it.. Hooked up gages and suction side was very high. Compressor not properly flowing free on. Suggests for customers to get consultation and customers agree. Customers also have a second unit that is not in the best condition. Would like consultation to get that changed as well. Signed customers up for taps plan. Collected payment and signature and left. Customers happy.


wade@totalairinc.net

wade@totalairinc.net Job Checkin

Customer concerned about unit not cooling properly. Checked condenser unit operation. Located error code (0 4 ) lock rotor lock out. Checked breaker and all electrical connections. Checked unit operation and reset error code. Checked refrigerant pressure and inspected equipment operation. Unit cooling well and amp draw on unit is normal. Customer approved Hard start kit.


wade@totalairinc.net

wade@totalairinc.net Job Checkin

Complete replacement of cutler hammer 50 amp breaker. Cycle and inspect equipment. All components are within there correct amp ranges. All incoming voltage is proper throughout the whole circuit, there are no dropouts. Unit is in operational order.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

No cool. Low voltage fuse popped due to a bad contactor. Replaced the contactoractor and fuse. Thermostat not working after short. Owner had a new thermostat to try try. Thermostat resetting shortly after powering up the system. Owner is going to get a new thermostat and we can return tomorrow to test system. Set transformer for 208v it was never changed from 230v


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Eaton 2 pole 50 amp breaker Replacement and checked heat strip. Unit is working properly and cooling at this time.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Customer concerned about unit not working properly. Breaker tripping in heat mode. Checked breaker and air handler wiring. Has #8 wire and 50 amp breaker. Heater is 8 kw and call for 50 amp breaker. Breaker is getting warm and tripping unit breaker. Heater amps are 35.2 and unit is cooling properly and drains at this time. Suggest to replace Eaton 50 two pole breaker in main panel. Follow up Monday


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Customer concerned about unit not cooling properly. Checked blower motor operation and inspected equipment cabinet. Checked thermostat calibration and filter location. Filter is good. Checked refrigerant levels and check test start up components. Unit is not running. Checked power and located tripped breaker in main breaker panel. Reset breaker and checked operation. Refrigerant levels are good and condenser unit is cooling properly. Customer concerned about a credit payment in full for tune up last month. Customer rescheduled due to illness. Please follow up with maintenance tune up.


Casey K.

Casey K. Job Checkin

Mitsubishi MXZ Floor- Standing Ductless Heat Pump Unit Ductless 2 Ton Mitsubishi MXZ Floor-Standing Ductless Heat Pump Unit Ductless 2.5 Ton Started install Mitsubishi air handler heads and line hide will return tomorrow to continue on working Ran line hide copper and can’t wire for the two 6000 be to use Andy 9000 BTU the two bedrooms in the office started to install 12,000 BTU in dining room will need to return Thursday to continue on working Install 12,000 BTU in sunroom and 15,000 be to you in living room and saw the condensation pump for 12,000 BTU and round copper through laundry room for both units both Units to the side yard started up system and charged to factory spec systems are operating to factory spec will need to return to complete other side of Hom customer left job before we were able to collect payment or get any signatures customer also took my folder and locked in his house and left so all the paperwork is in the homeowners house As we were leaving notice drain


matt@totalairinc.net

matt@totalairinc.net Job Checkin

System popping the the breaker as soon as it comes on. This was the breaker that feeds the air handler. I found this to be due to the disconnect failing and melting together so we changed it out. I tested the system while taking amp draw reading on the whole air handler as well as the motor and heaters in both heat and cool mode. All readings looked good it is unclear what may have caused the disconnect to fail, it seems it may have just been defective. Customer has signed up for the TAPS Annual Membership. Repairs are now complete system is currently operating correctly.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Customer concerned about unit not turning on. Check blower motor operation and thermostat. Located tripped breaker in main panel. Reset and test condenser operation. Unit cooling at this time. Suggest to replace breaker if fails again. Cutter hammer panel. Customer declined TAPS membership at this time


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Mini split in computer room not draining. After vaccuum and clearing, system still would not drain. Disassembled head and attempted to clean pan and entire unit. After disassembling I found drain line going uphill orver electrical whip through the wall. No room to relocate drain line. Home owner wants to replace the unit instead of reinstalling. Set appt for Corey to come.and quote a new unit.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Upon arrival customer told me mini split was leaking. I used a shop vac and sucked the drain line out. It still backed up. I pulled the cover off outside and it was disconnected. I connected the pipe and blew water out. Cleared the drain.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

System not cooling due to a tripped float safe t switch. Heavily cleared drain line at the common pvc drain outlet and poured condensate cleaner down and scraped evaporator drain pan of any gunk. Water flowing freely outside at this time. Left system in good working order.


Jason D.

Jason D. Job Checkin

Required Repairs: These are the minimum services required to get your system running today and does not include any recommended actions that I noticed. Cycled and inspected equipment. Found dual capacitor failed.instakked a new 70+5 warranty capacitor. Left system in good working order. Customer declined membership at this time.


Alex W.

Alex W. Job Checkin

Upon arrival the 16 seer Goodman split system was not cooling due to a locked rotor 04 error code reset code and reset power checked amps pressures etc. system is working in both stages correctly at this time possible intermittent board failure