CUSTOMER STATED: kitchen faucet bathroom faucet shower and toilet are all leaking water. TECHNICIAN NOTES: found the kitchen faucet bathroom faucet bathroom shower and toilet all leaking water. The fill valve in the toilet has failed the others have failed cartridges. Due to the age of the 2 faucets I recommend replacing the faucets. The shower can be rebuilt. RESOLUTION/RECOMMENDATIONS: Rebuild the toilet replace the kitchen and bathroom faucets and rebuild toilet JOB NOTES: pressure in the unit is 110 psi. 1” prv in ceiling above the unit that controls multiple units. Maintenance tech on site said that the prv is the units responsibility even though it controls multiple units. Customer going to figure out who is responsible for the prv with building manager on Tuesday. And call us back. Prv needs to be replaced before the other work done. Builds water may need to be shut off before hand in case the gate valve does not work at shutting the water completely off Could