6220 Lower York Rd
New Hope, PA 18938
(267)406-6050

Local Reviews
for pennington, nj


Job Locations
for pennington, nj

ryan_57@aol.com

ryan_57@aol.com Job Checkin

Radon test


ryan_57@aol.com

ryan_57@aol.com Job Checkin

Tested their water and the water is soft so Softner Is working properly. Sediment filter is very clean hardly any sediment. All time clocks are set correctly. All good.


ryan_57@aol.com

ryan_57@aol.com Job Checkin

Install a 8GPM UV sterilization light with a 2 x 10 sediment filter


Chris G.

Chris G. Job Checkin

Diagnosed well system, determined the tank was water logged


Chris G.

Chris G. Job Checkin

Install a dual (two tank) backwashing arsenic reduction system - (2) 10 x 44 mineral tanks - (2) Clack WS1 filter valves - (2) 1" Clack bypass valves - (2) Cubic feet of Metsorb distributed equally one cube per mineral tank Metsorb reduces type III and V arsenic) - (3) Sample ports Install a backwashing single tank 2.5 cubic foot catalytic carbon filtration system - (1) 13 x 54 mineral tank - (1) WS11 Clack filter valve - (1) 1" Clack bypass assembly - 2.5 Cubic feet off GAC (catalytic carbon) Install a metered 48,000 grain Clack water softener with a WS1 filter valve, bypass valves and brine tank. Install a four stage point of use reverse osmosis system at the kitchen sink. Clack products have a five year manufacturers warranty and our workmanship is warrantied for 90 days.


Chris G.

Chris G. Job Checkin

Fixed lateral leak


Chris G.

Chris G. Job Checkin

Hhhj


tommy61117@aol.com

tommy61117@aol.com Job Checkin

Install a PFAS reduction system with 2 cubic feet of SR 110 HP ion exchange media. Clack 9 x 48 mineral tanks, Clack 1" bypass valves and a sample port.. The tanks are configured lead/lag for redundancy and efficiency.


Chris G.

Chris G. Job Checkin

Install 1 HP 115V DAB booster pump w/wall mounting bracket


Chris G.

Chris G. Job Checkin

Excavate wellhead and raise with welded 6" steel. Install a new pitless adapter (if needed) Install a new 2 wire 230V submersible well pump and wire. Either a 1/2 HP or 3/4Hp pump. Replace existing well wire and linear footage to be determined. For purposes of this estimate we are assuming 200' of 12/2 flat jacket wire and this is subject to change. Install a new well cap and chlorinate the well. Site work restoration is the responsibility of the homeowner and we work to limit the area of disturbance. A NJ one call will be made on an emergency basis.


Chris G.

Chris G. Job Checkin

Replace power surged and damaged neutralizer filter valve circuitry/mother board Replace components as needed


Chris G.

Chris G. Job Checkin

.


Chris G.

Chris G. Job Checkin

Our six system UV light


Chris G.

Chris G. Job Checkin

Jet pump


Chris G.

Chris G. Job Checkin

- Locate and excavate wellhead. Most excavations are ~3 to 4 feet deep and in rare instances deeper. As work is progressing we will inform of any issues in this regard and any addition costs. - Raise by adding a welded pipe extension the 6" steel wellhead casing. For purposes of this estimate 4' of 6" steel casing is added and subject to change. Casing is billed on a linear foot bases. _ Install a pitless adapter and vermin proof health department approved well cap. - Install a 1/2 HP 2W 230V submersible well pump. For purposes of this estimate we are assuming a pump set depth of 100' and the pipe and wire length may vary. Both are billed on a linear foot bases. - Install a 33 gallon well tank with all associated fittings. - Remove all old equipment and dispose of same. - All labor, materials and equipment included. Fittings cost may vary and an itemized invoice will be provided. - A NJ One Call will be placed prior to excavation. NOTE: Site restoration is the responsibility of the