Logan P.

Logan P. Job Checkin

Planned maintenance checkout on 1 lennox heat pump and two lennox dual fuel systems with zoning and humidifiers. Found a few minor issues but was able to repair parts while I was doing checkouts. All systems showing normal operation at this time.


Logan P.

Logan P. Job Checkin

Complaint of no thermostat display on Goodman heat pump system. Found system with a undersized transformer causing contactor chattering with all heat stages calling. Solutions- Replaced 40va transformer with 70va and replaced 50 Amp 3 phase contactor out with new. Tested system in heat,cool, and emergency heat and system is now operating properly at this time.


Logan P.

Logan P. Job Checkin

Planned maintenance checkout on lennox heat pump system with emergency heat. System checked out great at this time.


Logan P.

Logan P. Job Checkin

Bid on replacement of existing drain lines to be ran into 1inc pvc main and then ran outdoors.


Logan P.

Logan P. Job Checkin

Planned maintenance checkout on lennox gas furnace. System looks great at this time.


Logan P.

Logan P. Job Checkin

Complaint of outdoor unit not running.


Logan P.

Logan P. Job Checkin

Replaced specialized zone damper and tested system operation. System looks great at this time.


Logan P.

Logan P. Job Checkin

Planned maintenance checkout on two mitibushi mini splits and 1 York split system heat pump. All systems look great at this time.


Logan P.

Logan P. Job Checkin

Planned maintenance checkout


Logan P.

Logan P. Job Checkin

A.c not cooling, Goodman heat pump system. Diagnosis- Found system low on r22 freon, added 2 pounds of new r22, checked system operation and also found bad-weak capacitor 35/5, replaced with new 35 and 5 and rechecked system operation. System showing normal operation at this time.


Logan P.

Logan P. Job Checkin

Replacement of indoor evaporator coil on Rheem heat pump system. System is now showing normal operation at this time. Would recommend annual service


Logan P.

Logan P. Job Checkin

Installation of new lennox signature series heat pump system.


Logan P.

Logan P. Job Checkin

Planned maintenance checkout on lennox heat pump system. System checked out great at this time.


Logan P.

Logan P. Job Checkin

A.c checkout on two zoned carrier systems. Both systems showing normal operation at this time, went ahead and got units cleaned out and filters changed. Also went over customer education as theses systems are new to them.


Logan P.

Logan P. Job Checkin

2 heat pump systems checkouts in a.c mode. Both systems check out great at this time.